A Tracking Compton-Scattering Imaging System for Hadron Therapy Monitoring
- 8 February 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (1), 144-150
- https://doi.org/10.1109/tns.2009.2031679
Abstract
Hadron therapy for, e.g., cancer treatment requires an accurate dose deposition (total amount and location). As a consequence, monitoring is crucial for the success of the treatment. Currently employed PET imaging systems are not able to provide information about the deposed dose fast enough to allow stopping the therapy in case of a discordance with the treatment plan. We are currently investigating an imaging system based on a combined Compton scattering and pair creation camera capable of imaging gamma rays up to 50 MeV. The camera would be able to measure the complete spectrum of emitted gamma rays during the therapy session. We have performed Monte Carlo simulations for three different proton beam energies in a typical hadron therapy scenario. They show that the location of the gamma-ray distribution decay and the falloff region of the deposed dose are related. The reconstructed images prove that the proposed system could provide the required imaging and dose location capabilities.Keywords
This publication has 13 references indexed in Scilit:
- MEGAlib: simulation and data analysis for low-to-medium-energy gamma-ray telescopesPublished by SPIE-Intl Soc Optical Eng ,2008
- Development of Electron Tracking Compton Camera using micro pixel gas chamber for medical imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- A Bayesian-based Method for Particle Track Identification in Low-energy Pair-creation TelescopesAIP Conference Proceedings, 2007
- Application of neural networks to the identification of the compton interaction sequence in compton imagersPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2007
- MeV γ-ray imaging detector with micro-TPCNew Astronomy Reviews, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Improved modeling of system response in list mode EM reconstruction of Compton scatter camera imagesIEEE Transactions on Nuclear Science, 2001
- List-mode maximum likelihood reconstruction of Compton scatter camera images in nuclear medicinePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1998
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission TomographyIEEE Transactions on Medical Imaging, 1987