Chemiluminescence detection in integrated post‐separation reactors for microchip‐based capillary electrophoresis and affinity electrophoresis
- 1 October 1998
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 19 (13), 2301-2307
- https://doi.org/10.1002/elps.1150191309
Abstract
Chemiluminescence (CL) detection based on the horseradish peroxidase (HRP) catalyzed reaction of luminol with peroxide was investigated as a post-separation detection scheme for microchip-based capillary electrophoresis. An integrated injector, separator and post-separation reactor was fabricated on planar glass wafers. The fluorescein conjugate of HRP (HRP-F1) was used as a sample for optimization of the CL detector response. In devices etched 10 μm deep, with an aluminum mirror integrated onto the backside of the detection zone to enhance collection efficiency, the detection limit, estimated at 3 standard deviations (SD) above background noise, for 1 nL injected sample plugs was 35 nM in HRP-F1. In devices etched 40 μm deep, 8 nL plugs gave a detection limit of 7 nM. Separation and CL detection of the products of an immunological reaction of a F(ab')2 fragment of the HRP conjugate of goat anti-mouse immunoglobulin G (IgG) with mouse IgG was performed on-chip. A linear calibration curve was obtained for the decrease in peak height of the HRP conjugate (53 μg/mL) with increasing mouse IgG (0–60 μg/mL). When microperoxidase was used as an internal standard, the R2 value of a linear least-squares fit was 0.9867, and the relative errors in the slope and intercept were ± 5.8 and ± 1.3%, respectively.Keywords
This publication has 31 references indexed in Scilit:
- Integrated Capillary Electrophoresis Devices with an Efficient Postcolumn Reactor in Planar Quartz and Glass ChipsAnalytical Chemistry, 1996
- Microchip Electrophoretic Immunoassay for Serum CortisolAnalytical Chemistry, 1996
- Rate constants for reactions of horseradish peroxidase compounds I and II with 4-substituted arylboronic acidsCanadian Journal of Chemistry, 1994
- Chemiluminescence and immunoassaysJournal of Pharmaceutical and Biomedical Analysis, 1994
- Capillary Zone Electrophoretic Separation of Protein Labeled with Rhodamine B Isothiocyanate and Its On-Line Chemiluminescence DetectionBulletin of the Chemical Society of Japan, 1994
- Micromachining of capillary electrophoresis injectors and separators on glass chips and evaluation of flow at capillary intersectionsAnalytical Chemistry, 1994
- Affinity probe capillary electrophoresis: analysis of recombinant human growth hormone with a fluorescent labeled antibody fragmentAnalytical Chemistry, 1994
- Glass chips for high-speed capillary electrophoresis separations with submicrometer plate heightsAnalytical Chemistry, 1993
- Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a ChipScience, 1993
- Planar glass chips for capillary electrophoresis: repetitive sample injection, quantitation, and separation efficiencyAnalytical Chemistry, 1993