A Comparison of the Efficacy and Toxicity of and Intraocular Pressure Response to Viscous Solutions in the Anterior Chamber
- 1 December 1986
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 104 (12), 1819-1824
- https://doi.org/10.1001/archopht.1986.01050240093047
Abstract
• An intraocular-lens abrasion test, vital dye staining, and scanning electron microscopy were used for an in vitro comparison of endothelial protection offered by four viscous solutions of 1% sodium hyaluronate (Healon), 3% sodium hyaluronate (AmVisc), 4% chondroitin sulfate (Viscoat), and 2% methylcellulose. Wide-field specular microscopy with analysis of endothelial cell density and morphologic evaluation, pachymetry, and intraocular pressure measurements were also used to study the toxicity of the viscous solutions in an in vivo cat model with and without anterior chamber washout. All four solutions provided complete endothelial protection from mechanical trauma. Endothelial cell density and morphologic nature were unaffected during the in vivo toxicity study. A mild increase in intraocular inflammation occurred at one and two days after intraocular injection with all four viscous solutions. Intraocular pressure elevations peaked within four hours after instillation of the viscous solutions and were significantly reduced by anterior chamber washout.This publication has 22 references indexed in Scilit:
- Obstruction of Aqueous Outflow by Sodium Hyaluronate in Enucleated Human EyesAmerican Journal of Ophthalmology, 1983
- Methylcellulose and lens implantation.British Journal of Ophthalmology, 1983
- The use of Healon® in anterior chamber lens implantationAmerican Intra-Ocular Implant Society Journal, 1982
- Effects of Extracapsular Implant Techniques on Endothelial DensityArchives of Ophthalmology (1950), 1982
- HealonR in anterior chamber lens implantationAmerican Intra-Ocular Implant Society Journal, 1981
- Intracapsular and extracapsular technique of lens implantation with Healon®American Intra-Ocular Implant Society Journal, 1980
- Inflammation and intraocular pressure after the use of Healon® in intraocular lens surgeryAmerican Intra-Ocular Implant Society Journal, 1980
- Morphology of graft endothelium and donor age.British Journal of Ophthalmology, 1980
- Non-Immunogenicity of a Purified Sodium Hyaluronate Preparation in ManInternational Archives of Allergy and Immunology, 1979
- Studies of the Irritating Action of MethylcelluloseArchives of Ophthalmology (1950), 1959