Automated detection of malaria-associated intraleucocytic haemozoin by Cell-Dyn CD4000 depolarization analysis
- 18 March 2003
- journal article
- clinical trial
- Published by Wiley in Clinical and Laboratory Haematology
- Vol. 25 (2), 77-86
- https://doi.org/10.1046/j.1365-2257.2003.00496.x
Abstract
Laboratory tests for malaria are only performed if there is clinical suspicion of the disease, and a missed diagnosis contributes substantially to morbidity and mortality. Malaria parasites produce haemozoin, which is able to depolarize light and this allows the automated detection of malaria during routine complete blood count analysis (CBC) with some Abbott Cell-Dyn instruments. In this study, we evaluated the Cell-Dyn CD4000 with 831 blood samples submitted for malaria investigations. Samples were categorized as malaria negative (n = 417), convalescent malaria (n = 64) or malaria positive (n = 350) by reference to thin/thick film microscopy, 'rapid test' procedures, polymerase chain reaction analysis and clinical history. With regard to CD4000 depolarization analysis, a malaria positive CD4000 pattern was ascribed to samples that showed one or more abnormal depolarizing purple events, which corresponded to monocytes containing ingested malaria pigment (haemozoin). Positive CD4000 patterns were observed in 11 of 417, 50 of 64 and 281 of 350 of malaria negative, convalescent malaria and malaria positive samples respectively. The specificity and positive predictive values for malaria (active and convalescent) were very high (97.4 and 96.8%, respectively), while sensitivity and negative predictive values were 80.0 and 83.0% respectively. Depolarization analysis was particularly effective for Plasmodium falciparum malaria but there was lower detection sensitivity for White compared with Black African patients. CD4000 90 degrees depolarization vs 0 degrees analysis revealed a proportion of samples with small nonleucocyte-associated depolarizing particles. Appearance of such events in the form of a discrete cluster was associated with P. vivax rather than P. falciparum infection.Keywords
This publication has 26 references indexed in Scilit:
- Avoiding Misdiagnosis of Malaria: A Novel Automated Method Allows Specific Diagnosis, even in the Absence of Clinical SuspicionEmerging Infectious Diseases, 1999
- AUTOMATED MALARIA DETECTIONBritish Journal of Haematology, 1999
- Formation of haemozoin/β‐haematin under physiological conditions is not spontaneousFEBS Letters, 1996
- Intraleucocytic malaria pigment and prognosis in severe malariaTransactions of the Royal Society of Tropical Medicine and Hygiene, 1995
- Quinoline anti‐malarial drugs inhibit spontaneous formation of β‐haematin (malaria pigment)FEBS Letters, 1994
- Analysis of malaria pigment from Plasmodium falciparumJournal of Pharmacological and Toxicological Methods, 1994
- Accuracy of routine laboratory diagnosis of malaria in the United Kingdom.Journal of Clinical Pathology, 1994
- Inhibition by chloroquine of a novel haem polymerase enzyme activity in malaria trophozoitesNature, 1992
- A novel detection of a single plasmodium falciparum in infected bloodBiochemical and Biophysical Research Communications, 1991
- Haematological Alterations in Acute MalariaScandinavian Journal of Haematology, 1982