A vibrator prevents streaming during close-arterial infusion into the kidney
Open Access
- 1 April 2004
- journal article
- Published by American Physiological Society in American Journal of Physiology-Renal Physiology
- Vol. 286 (4), F643-F646
- https://doi.org/10.1152/ajprenal.00290.2003
Abstract
Close-arterial infusion of test substances allows one to study the responses of a selected vascular bed without inducing confounding systemic effects. Unfortunately, laminar flow patterns within the artery cause streaming of the injected factor, so that distribution within the target organ is not homogeneous. We describe a reliable method of overcoming these problems. Specifically, we attach a vibrator (i-Vibe egg) to the syringe containing the test substance. We showed that, without vibration, infusion of a solution of Evans blue (0.5% wt/vol) results in uneven distribution of the dye in the kidney. Vibration of the syringe during infusion allows for uniform coloration of the kidney surface. There is also functional improvement of drug distribution during vibration. Renal blood flow was measured during intrarenal infusion of phenylephrine (150 μl, 0.05–0.5 μg). Vibration caused a significant leftward shift in the dose-response curve, i.e., the phenylephrine-induced reduction in renal blood flow was enhanced by vibration. This cheap, simple method for ensuring adequate mixing of intra-arterially infused substances will facilitate not only the study of renal function in the rat but also infusion of test and therapeutic substances into other organs.Keywords
This publication has 16 references indexed in Scilit:
- Inhibitors of 20-Hydroxyeicosatetraenoic Acid Reduce Renal Vasoconstrictor ResponsivenessJournal of Pharmacology and Experimental Therapeutics, 2003
- Anin VitroFlow Model to Study Streaming during Pelvic Intra-arterial Drug InfusionsGynecologic Oncology, 1995
- Hepatic artery model for evaluating the distribution of intraarterial chemotherapy infusion: nonpulsed versus pulsed infusions.Radiology, 1989
- Mixing Problems of Low Flow Hepatic Artery Infusion Improvement with Small Caliber Double Lumen Balloon CathetersInvestigative Radiology, 1988
- Arterial Drug Infusion: Pharmacokinetic Problems and PitfallsJNCI Journal of the National Cancer Institute, 1988
- Intravascular Streaming and Variable Delivery to Brain following Carotid Artery Infusions in the Sprague-Dawley RatJournal of Cerebral Blood Flow & Metabolism, 1988
- Renal medullary plasma flow rate and reabsorption of salt and water from inner medullary collecting ductCanadian Journal of Physiology and Pharmacology, 1987
- Pulsed arterial infusions. Chemotherapeutic implicationsCancer, 1986
- Drug streaming during intra-arterial chemotherapyJournal of Neurosurgery, 1986
- Mixing studies during intracarotid artery infusions in an in vitro modelJournal of Neurosurgery, 1986