Abstract
The identification of ischemic but viable myocardium by thallium exercise scintigraphy is often imprecise, since many of the perfusion defects that develop in ischemic myocardium during exercise do not "fill in" on subsequent redistribution images. We hypothesized that a second injection of thallium given after the redistribution images were taken might improve the detection of ischemic but viable myocardium.Keywords
This publication has 21 references indexed in Scilit:
- The effect of coronary artery bypass grafting on left ventricular systolic function at rest: Evidence for preoperative subclinical myocardial ischemiaThe American Journal of Cardiology, 1988
- Reversible ischemic left ventricular dysfunction: Evidence for the “hibernating myocardium”Journal of the American College of Cardiology, 1986
- Reversibility of Cardiac Wall-Motion Abnormalities Predicted by Positron TomographyNew England Journal of Medicine, 1986
- The persistent defect on exercise thallium imaging and its fate after myocardial revascularization: Does it represent scar or ischemia?American Heart Journal, 1985
- Improved regional ventricular function after successful surgical revascularizationJournal of the American College of Cardiology, 1984
- Prospective assessment of regional myocardial perfusion before and after coronary revascularization surgery by Quantitative Thallium-201 scintigraphyJournal of the American College of Cardiology, 1983
- The stunned myocardium: prolonged, postischemic ventricular dysfunction.Circulation, 1982
- Preoperative Prediction of Reversible Myocardial Asynergy by Postexercise Radionuclide VentriculographyNew England Journal of Medicine, 1982
- Myocardial imaging with thallium-201 at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography.Circulation, 1977