Particle Clearance from the Respiratory Tract as a Test of Toxicity: Effect of Ozone on Short and Long Term Clearance
Open Access
- 1 January 1981
- journal article
- research article
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 2 (2), 111-120
- https://doi.org/10.3109/01902148109052307
Abstract
The ability of the lung to mechanically remove inhaled deposited particles is an important mammalian defense mechanism that can be evaluated in the laboratory. Experiments that measure clearance kinetics have been performed by various investigators using human as well as large and small laboratory animals as subjects. Several agents have been shown to significantly alter clearance phenomena in the lung. This paper describes quantitative clearance experiments that used radioactive tracer particles to assess lung damage after exposure of rats to ozone, a photochemical air-pollutant gas. Radioactively labeled tracer microspheres were inhaled by groups of 30 rats prior to exposure to ozone. Ozone levels studied were 0.4, 0.8, and 1.0 ppm and all exposures were 4 hr in length. These exposures caused a delay in the early (0-50 hr postdeposition) clearance and an acceleration in the late (50-300 hr postdeposition) clearance rate of the tracer particles. Dose response curves show that clearance was affected more by the higher concentrations of ozone.This publication has 16 references indexed in Scilit:
- Adaptations to Ozone in Reference to Mucociliary ClearanceArchives of environmental health, 1979
- Labeling of monodisperse polystyrene microspheres with tightly bound 51CrAihaj Journal, 1978
- Factors Influencing the Deposition of Inhaled ParticlesEnvironmental Health Perspectives, 1976
- Production and labelling of monodisperse polystyrene and polystyrene- vinyltoluene copolymer latexesThe International Journal of Applied Radiation and Isotopes, 1975
- Effects of Cigarette Smoke Components on Bronchial Clearance in the DonkeyArchives of environmental health, 1974
- Ozone and the antibacterial defense mechanisms of the murine lungArchives of Internal Medicine, 1971
- The Preparation of Bromine-82 and Iodine-131 Labelled Polystyrene Microspheres With Diameters from 0·1 to 30 MicronsAnnals of Occupational Hygiene, 1970
- A multi-stage, low flow rate cascade impactorJournal of Aerosol Science, 1970
- On the Role of Particle Size in the Dissolution of Lung BurdensHealth Physics, 1967
- A Point-to-Plane Electrostatic Precipitator for Particle Size SamplingAihaj Journal, 1964