Performance of a Portable Whole-Body Mouse Exposure System
- 1 January 2004
- journal article
- research article
- Published by Taylor & Francis in Inhalation Toxicology
- Vol. 16 (9), 657-662
- https://doi.org/10.1080/08958370490464670
Abstract
A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 μm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent exposure. Airflow mixing and the potential for stagnant areas within the compartments were modeled using computational fluid dynamic modeling (CFD). CFD analysis showed no stagnant areas and good mixing throughout the exposure cage. The actual performance of the exposure system was determined for 0.5 to 2.0 μm diameter aerosols by measuring (1) uniformity of aerosol distribution and (2) particle deposition in the tracheobronchial and pulmonary regions of mice exposed in the system. A 0.6-μm MMAD (GSD = 2.0) cigarette smoke aerosol was used to experimentally measure the uniformity of aerosol distribution to the nine individual compartments. The average data from three runs showed no statistically significant difference among individual compartments. Particle deposition efficiency in adult male BALB/c mice was measured after exposure (30 min) in the system using monodisperse fluorescent polystyrene latex particles (0.5, 1, and 2 μm aerodynamic diameter). The measured deposition efficiency in this mobile exposure system for the combined tracheobronchial and pulmonary regions of the adult male BALBc mice was 21% for 0.5 μm, 11% for 1.0 μm, and 6.5% for 2.0 μm particles. These deposition efficiencies are similar to those reported for mice exposed in a nose-only exposure system, which indicates that particle losses to animal fur and exposure system surfaces were acceptable.Keywords
This publication has 12 references indexed in Scilit:
- A Small Whole-Body Exposure Chamber for Laboratory UseInhalation Toxicology, 2003
- Versatile aerosol concentration enrichment system (VACES) for simultaneous in vivo and in vitro evaluation of toxic effects of ultrafine, fine and coarse ambient particles Part II: Field evaluationJournal of Aerosol Science, 2001
- Versatile aerosol concentration enrichment system (VACES) for simultaneous in vivo and in vitro evaluation of toxic effects of ultrafine, fine and coarse ambient particles Part I: Development and laboratory characterizationJournal of Aerosol Science, 2001
- Physical characterization of incense aerosolsScience of The Total Environment, 1996
- Comparative Evaluation of Nose-Only Versus Whole-Body Inhalation Exposures for Rats—Aerosol Characteristics and Lung DepositionInhalation Toxicology, 1990
- Improvement of Aerosol Distribution in Whole-Body Inhalation Exposure ChambersInhalation Toxicology, 1989
- Regional Deposition of Inhaled Monodisperse Coarse and Fine Aerosol Particles in Small Laboratory AnimalsAnnals of Work Exposures and Health, 1988
- Studies of the Temporal and Spatial Distribution of Aerosols in Multi-Tiered Inhalation Exposure ChambersAihaj Journal, 1986
- Designs and operational characteristics of inhalation exposure equipment — A reviewFundamental and Applied Toxicology, 1983
- The Dilution of Monodisperse Suspensions for AerosolizationAihaj Journal, 1968