Evaluation of thermal diffusion factor and diffusion coefficient from measurements on a trennschaukel

Abstract
Measurements have been taken on a glass trennschaukel of eight tubes for the Ar-He system as a function of composition and with its hot and cold bulbs at 100°c and 0°c. For each mixture, several speeds for the mechanical push-pull motion of the gas which cover a wide enough range were tried. The results have been interpreted to determine the thermal diffusion factor α T, in conventional fashion as well as on the basis of a theory characterizing the low speed operation, developed here. Four such different possibilities of α t evaluation are discussed and values compared with the traditional ones obtained from the convection-free two-bulb apparatus. Lastly we discuss also in brief the prospect of estimating the diffusion coefficient as an important byproduct from measurements on trennschaukel runs.