Cannula thrombophlebitis: a study in volunteers comparing polytetrafluoroethylene, polyurethane, and polyamide-ether-elastomer cannulae
- 1 April 1989
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 33 (3), 223-231
- https://doi.org/10.1111/j.1399-6576.1989.tb02895.x
Abstract
Cannulae made of polytetrafluoroethylene (PTFE: n = 11), thermoplastic polyether-urethane (TPEU: = 11), and a new test material, polyamide-ether-elastomer (XLON: n = 10) were inserted into the veins of the dorsum of the hand in 32 healthy volunteers (10 women and 22 men), 21-50 years old. The cannulae were intended to be left in place for 5 days. No infusion was given and the dressings were not exchanged. The resulting thrombophlebitis, defined as two or more of the symptoms pain, redness, oedema and hardness, was estimated on a scale which took into account the incidence, location, intensity, and duration of the symptoms. Except for one volunteer in the XLON group, all the volunteers developed thrombophlebitis, generally observed on the third day of cannulation, and being more frequent and intense over the cannulae (P < 0.001) and at the tip (P < 0.01) than at the insertion sites. Pain and oedema were, on the whole, the most frequent and severe symptoms during the period of indewelling. After withdrawal, hardness was the most intense, and together with pain, the most long-lasting (up to 10 days) symptom. The differences between the materials in thrombophlebitis incidence and intensity were statistically significant only when each symptom was analysed separately. Thus, the PTFE cannulae caused more pain and hardness (probably because of greater platelet adhesion and a relatively greater stiffness), while the TPEU and XLON cannulae produced more periphlebitis (redness and oedema), probably because of potentially irritant and antigenic substances leaking from them (polyurethane oligomers and polyamide/polyethyleneglycol oligomers).Keywords
This publication has 14 references indexed in Scilit:
- Microparticulate-Induced PhlebitisNew England Journal of Medicine, 1985
- Methods for Measuring Clinical Pain in HumansActa Anaesthesiologica Scandinavica, 1982
- A prospective trial comparing a silicone elastomer intravenous cannula (Visis) with a polytetrafluoroethylene cannula (Cathlon)British Journal of Surgery, 1982
- Effects of roughness on the thrombogenicity of a plasticJournal of Biomedical Materials Research, 1981
- Experimental infusion thrombophlebitisIntensive Care Medicine, 1979
- IN VIVO EVALUATION OF PROSTHETIC SURFACESAnnals of the New York Academy of Sciences, 1977
- Venous reactions related to in-dwelling plastic cannulae: a prospective clinical trialCurrent Medical Research and Opinion, 1976
- Venous reaction to plastic intravenous cannulae: influence of cannula compositionCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1972
- Postinfusion PhlebitisAnesthesia & Analgesia, 1970
- Phlebitis from Plastic Intravenous CathetersAnesthesiology, 1964