An unseen danger: Frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance*
Top Cited Papers
- 1 August 2009
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 37 (8), 2345-2349
- https://doi.org/10.1097/ccm.0b013e3181a067d4
Abstract
Objectives: To evaluate the frequency of unsuspected posterior vessel wall penetration of the internal jugular vein during ultrasound-guided needle cannulation. Design: Prospective, single-blinded observational study. Setting: Urban level I emergency department with an annual census of 80,000. Patients: Residents who had previously completed a 2-day ultrasound course including a 3-hr didactic and hands-on session on ultrasound-guided central venous cannulation. Interventions: Residents were asked to place an ultrasound-guided catheter on a human torso mannequin. Residents used a short-axis approach for ultrasound guidance. During the procedure, an 8–4 MHz convex (endocavity) transducer was used to observe the path of the resident’s needle without interference with the placement procedure. Measurements and Main Results: Unknown to residents, researchers tracked the frequency of posterior wall penetration and the final needle location when the resident felt that optimal needle placement was achieved in the lumen of the internal jugular. Residents were also asked to rate their confidence regarding appropriate final needle position on a 10-point Likert scale. Statistical analysis consisted of descriptive statistics and Spearman correlation analysis. A total of 25 residents participated. All had placed at least one ultrasound-guided central catheter previously. The median number of previous ultrasound-guided cannulations was 8.0. Sixteen (64%) residents accidentally penetrated the posterior wall of the internal jugular vein during cannulation. The median number of posterior wall penetrations was 1.0 for all residents. In six cases the final location of the needle was through the posterior wall and deep to the venous lumen. In five of these cases the carotid artery was actually mistakenly penetrated. Median confidence by residents regarding appropriate needle placement was 8.0 out of 10. More training and more ultrasound-guided catheters placed were associated with fewer posterior wall penetrations (p = .04). Conclusions: In this study, residents accidentally penetrated the posterior vessel wall of the internal jugular in a lifelike vascular access mannequin in the majority of cases. These results suggest that care must be taken even with ultrasound-guided central catheter placement and that alternative ultrasound guidance techniques, such as visualization of the vein and needle in longitudinal axis, should be considered.Keywords
This publication has 23 references indexed in Scilit:
- Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The Third Sonography Outcomes Assessment Program (SOAP-3) Trial*Critical Care Medicine, 2005
- Short-axis versus Long-axis Approaches for Teaching Ultrasound-guided Vascular Access on a New Inanimate ModelAcademic Emergency Medicine, 2003
- Ultrasonic locating devices for central venous cannulation: meta-analysisBMJ, 2003
- Use of ultrasound to place central linesJournal of Critical Care, 2002
- The use of ultrasound for the placement of dialysis cathetersNephrology Dialysis Transplantation, 1998
- Improvement of internal jugular vein cannulation using an ultrasound-guided techniqueIntensive Care Medicine, 1997
- Ultrasound guidance for placement of central venous cathetersCritical Care Medicine, 1996
- Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique.Circulation, 1993
- Ultrasound-Guided Cannulation of the Internal Jugular Vein. A Prospective, Randomized StudyAnesthesia & Analgesia, 1991
- Ultrasound Guidance Improves the Success Rate of Internal Jugular Vein CannulationChest, 1990