Continuous cytometric bead processing within a microfluidic device for bead based sensing platforms
- 1 January 2007
- journal article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (5), 588-595
- https://doi.org/10.1039/b703808a
Abstract
A microfluidic device for continuous biosensing based on analyte binding with cytometric beads is introduced. The operating principle of the continuous biosensing is based on a novel concept named the “particle cross over” mechanism in microfluidic channels. By carefully designing the microfluidic network the beads are able to “cross-over” from a carrier fluid stream into a recipient fluid stream without mixing of the two streams and analyte dilution. After crossing over into the recipient stream, bead processing such as analyte-bead binding may occur. The microfluidic device is composed of a bead solution inlet, an analyte solution inlet, two washing solution inlets, and a fluorescence detection window. To achieve continuous particle cross over in microfluidic channels, each microfluidic channel is precisely designed to allow the particle cross over to occur by conducting a series of studies including an analogous electrical circuit study to find optimal fluidic resistances, an analytical determination of device dimensions, and a numerical simulation to verify microflow structures within the microfluidic channels. The functionality of the device was experimentally demonstrated using a commercially available fluorescent biotinylated fluorescein isothiocyanate (FITC) dye and streptavidin coated 8 µm-diameter beads. After, demonstrating particle cross over and biotin-streptavidin binding, the fluorescence intensity of the 8 µm-diameter beads was measured at the detection window and linearly depends on the concentration of the analyte (biotinylated FITC) at the inlet. The detection limit of the device was a concentration of 50 ng ml−1 of biotinylated FITC.This publication has 33 references indexed in Scilit:
- An Analysis of Oxygen Consumption and Oxygen Delivery in Euthermic Infants After Cardiopulmonary Bypass With Modified UltrafiltrationThe Annals of Thoracic Surgery, 2004
- Microreactor and electrochemical detectors fabricated using Si and EPON SU-8Sensors and Actuators B: Chemical, 2000
- Cytokine and complement levels in patients undergoing cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1993
- Complement activation during cardiopulmonary bypass in infants and childrenThe Journal of Thoracic and Cardiovascular Surgery, 1993
- The cell in shock: the origin of multiple organ failureResuscitation, 1991
- Complement activation during major operations with or without cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1987
- Organ dysfunction after cardiopulmonary bypass. A systemic inflammatory reaction initiated by the extracorporeal circuitIntensive Care Medicine, 1987
- Effects of Protamine Administration after Cardiopulmonary Bypass on Complement, Blood Elements, and the Hemodynamic StateThe Annals of Thoracic Surgery, 1986
- Complement and the damaging effects of cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1983
- Stochastic flow in capillary blood vesselsMicrovascular Research, 1973