Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model
- 1 December 1997
- journal article
- Published by Wiley in Medical Physics
- Vol. 24 (12), 1975-1985
- https://doi.org/10.1118/1.598111
Abstract
A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other head structures, respectively. The effect of the finite size of the extra-focal source was modeled by a convolution of the source fluence distribution with the collimator aperture function. Relative photon output in air (Sc) and in phantom (Scp) were computed using the convolution method with this new photon beam model. Our results showed that in a 10 MV photon beam, the Sc, Sp (phantom scatter factor), and Scp factors increased by 11%, 10%, and 22%, respectively, as the field size changed from 3 x 3 cm2 to 40 x 40 cm2. The variation of the Sc factor was contributed mostly by an increase of the extra-focal radiation with field size. The radiation backscattered into the monitor chamber inside the accelerator head affected the Sc by about 2% in the same field range. The output factors in elongated fields, asymmetric fields, and blocked fields were also investigated in this study. Our results showed that if the effect of the backscattered radiation was taken into account, output factors in these treatment fields can be predicted accurately by our convolution algorithm using the dual source photon beam model.Keywords
This publication has 31 references indexed in Scilit:
- Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalismMedical Physics, 1995
- Output factors for fields defined by four independent collimatorsMedical Physics, 1995
- Relative output factors of asymmetric megavoltage beamsRadiotherapy and Oncology, 1994
- Output factors for blocked fieldsThe British Journal of Radiology, 1993
- Head‐scatter factors in rectangular photon fieldsMedical Physics, 1993
- The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantomRadiotherapy and Oncology, 1991
- Scatter factor corrections for elongated fieldsMedical Physics, 1989
- A convolution method for constructing primary beam profiles in the presence of beam modifiersMedical Physics, 1988
- Dosimetric characteristics of a 6 MV photon beam from a linear accelerator with asymmetric collimator jawsInternational Journal of Radiation Oncology*Biology*Physics, 1988