A COMPARATIVE STUDY OF TEN ELECTRICAL METERS FOR DETERMINING MOISTURE CONTENT OF WHEAT

Abstract
Ten electrical moisture meters were tested with 159 samples of Canadian hard red spring wheat, of Grades 1, 2, 3, and 4 Northern, representing a moisture range of 11 to 17%. The two-stage vacuum oven and Brown–Duvel methods were used as bases of comparison. Regression equations, standard errors of estimate, and data on temperature effects are reported. The standard error of estimate of vacuum oven results was 0.15% for the Brown–Duvel method, 0.23% for the Tag–Heppenstall meter, and 0.28% for the Universal meter. Other meters had higher errors of estimate.
Keywords