Evaluation of Five Decontamination Methods for Filtering Facepiece Respirators
Top Cited Papers
Open Access
- 4 October 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 53 (8), 815-827
- https://doi.org/10.1093/annhyg/mep070
Abstract
Concerns have been raised regarding the availability of National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One possible strategy to mitigate a respirator shortage is to reuse FFRs following a biological decontamination process to render infectious material on the FFR inactive. However, little data exist on the effects of decontamination methods on respirator integrity and performance. This study evaluated five decontamination methods [ultraviolet germicidal irradiation (UVGI), ethylene oxide, vaporized hydrogen peroxide (VHP), microwave oven irradiation, and bleach] using nine models of NIOSH-certified respirators (three models each of N95 FFRs, surgical N95 respirators, and P100 FFRs) to determine which methods should be considered for future research studies. Following treatment by each decontamination method, the FFRs were evaluated for changes in physical appearance, odor, and laboratory performance (filter aerosol penetration and filter airflow resistance). Additional experiments (dry heat laboratory oven exposures, off-gassing, and FFR hydrophobicity) were subsequently conducted to better understand material properties and possible health risks to the respirator user following decontamination. However, this study did not assess the efficiency of the decontamination methods to inactivate viable microorganisms. Microwave oven irradiation melted samples from two FFR models. The remainder of the FFR samples that had been decontaminated had expected levels of filter aerosol penetration and filter airflow resistance. The scent of bleach remained noticeable following overnight drying and low levels of chlorine gas were found to off-gas from bleach-decontaminated FFRs when rehydrated with deionized water. UVGI, ethylene oxide (EtO), and VHP were found to be the most promising decontamination methods; however, concerns remain about the throughput capabilities for EtO and VHP. Further research is needed before any specific decontamination methods can be recommended.Keywords
This publication has 22 references indexed in Scilit:
- Development of a Test System To Apply Virus-Containing Particles to Filtering Facepiece Respirators for the Evaluation of Decontamination ProceduresApplied and Environmental Microbiology, 2009
- 2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care SettingsAmerican Journal of Infection Control, 2007
- Occupational risk factors for asthma among nurses and related healthcare professionals in an international studyOccupational and Environmental Medicine, 2007
- Asthma, chronic bronchitis, and exposure to irritant agents in occupational domestic cleaning: a nested case-control studyOccupational and Environmental Medicine, 2005
- Impacts of Goethite Particles on UV Disinfection of Drinking WaterApplied and Environmental Microbiology, 2005
- Fans, Filters, or Rays? Pros and Cons of the Current Environmental Tuberculosis Control TechnologiesInfection Control & Hospital Epidemiology, 1993
- Irritation factors of sodium hypochlorite solutions in human skinContact Dermatitis, 1990
- Sensitization to sodium hypochlorite causing hand dermatitisContact Dermatitis, 1986
- Sodium hypochlorite dermatitisContact Dermatitis, 1984
- Interspecies comparisons of skin irritancyToxicology and Applied Pharmacology, 1975