Blood-perfused working isolated rat heart

Abstract
We describe a method for perfusion of a working isolated rat heart with washed erythrocytes suspended in a Krebs-Henseleit bicarbonate buffer containing bovine albumin (fraction V). With washed pig red cells, as hematocritwas varied between 0 and 40%, coronary flow (CF), aortic flow (AF), external work (W), and myocardial oxygen consumption (MVO2) were measured. Hemodynamic data at a hematocrit of 30% (CF = 5.4 +/- 0.7 ml/min per g, AF = 75 +/- 8 ml/min per g) were identical with those reported for the intact animal.Coronary sinus PO2 was highest with a red cell-free perfusate suggesting that coronary flow is partially shunted. Human red cells obtained from bankedblood, were tried also with success. With careful filtration, the preparation is stable for 2 h and well suited for study of the dynamics of myocardial oxygen delivery.