A rapid and efficient mass spectrometric method for the analysis of explosives
- 3 September 2002
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (19), 1883-1891
- https://doi.org/10.1002/rcm.799
Abstract
The high explosives trinitrotoluene, nitroglycerine, pentaerythritol tetranitrate and hexahydro-1,3,5-trinitro-1,3,5-triazine are efficiently ionised under negative ion atmospheric pressure chemical ionisation (APCI) conditions. The limit of detection is improved, in some cases by several orders of magnitude, by complexation with chlorine demonstrating this to be a highly suitable method for enhancing the detection capabilities for explosives. The spectra produced from introduction of the analytes in a liquid matrix, with and without chlorine present, contain a number of ions that arise through secondary processes including breakdown and adduct formation. Sample introduction into an APCI source in air, via a heated-plate inlet with a supplementary feed of dichloromethane, produces improved response for the chloride adducts of the analytes and minimises their decomposition during analysis. The tandem mass spectra produced from the chloride adducts are simple. Optimisation of the trapping parameters of the ion trap detector enhances selected transitions, yields highly reproducible spectra and improves the limits of detection for MS/MS analysis. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
This publication has 18 references indexed in Scilit:
- Formation of gas-phase clusters monitored during electrospray mass spectrometry: a study of quaternary ammonium pesticidesRapid Communications in Mass Spectrometry, 2001
- A critical review of ion mobility spectrometry for the detection of explosives and explosive related compoundsTalanta, 2001
- PrefaceTalanta, 2001
- Determination of nitroaromatic, nitramine, and nitrate ester explosives in soil by gas chromatography and an electron capture detectorTalanta, 2001
- Tandem mass spectrometric analysis of quaternary ammonium pesticidesRapid Communications in Mass Spectrometry, 2001
- Peer Reviewed: Drugs on Money.Analytical Chemistry, 2000
- Rapid screening of banknotes for the presence of controlled substances by thermal desorption atmospheric pressure chemical ionisation tandem mass spectrometryThe Analyst, 1999
- EXPLOSIVES DETECTION: A Challenge for Physical ChemistryAnnual Review of Physical Chemistry, 1998
- Mass spectral fragmentation pathways in RDX and HMX. A mass analyzed ion kinetic energy spectrometric/collisional induced dissociation studyJournal of Mass Spectrometry, 1982