Plug flow cytometry extends analytical capabilities in cell adhesion and receptor pharmacology
Open Access
- 7 February 2001
- Vol. 43 (3), 211-216
- https://doi.org/10.1002/1097-0320(20010301)43:3<211::aid-cyto1052>3.0.co;2-3
Abstract
Background Plug flow cytometry is a recently developed system for the automated delivery of multiple small boluses or “plugs” of cells or particles to the flow cytometer for analysis. Important system features are that sample plugs are of precisely defined volume and that the sample vessel need not be pressurized. We describe how these features enable direct cell concentration determinations and novel ways to integrate flow cytometers with other analytical instruments. Methods Adhesion assays employed human polymorphonuclear neutrophils (PMNs) loaded with Fura Red and Chinese hamster ovary (CHO) cells cotransfected with genes for green fluorescent protein (GFP) and human P‐selectin. U937 cells expressing the human 7‐transmembrane formyl peptide receptor were loaded with the fluorescent probe indo‐1 for intracellular ionized calcium determinations. A computer‐controlled syringe or peristaltic pump loaded the sample into a sample loop of the plug flow coupler, a reciprocating eight‐port valve. When the valve position was switched, the plug of sample in the sample loop was transported to the flow cytometer by a pressure‐driven fluid line. Results In stirred mixtures of PMNs and CHO cells, we used plug flow cytometry to directly quantify changes in concentrations of nonadherent singlet PMNs. This approach enabled accurate quantification of adherent PMNs in multicell aggregates. We constructed a novel plug flow interface between the flow cytometer and a cone‐plate viscometer to enable real‐time flow cytometric analysis of cell‐cell adhesion under conditions of uniform shear. The High Throughput Pharmacology System (HTPS) is an instrument used for automated programming of complex pharmacological cell treatment protocols. It was interfaced via the plug flow coupling device to enable rapid (<5 min) flow cytometric characterization of the intracellular calcium dose‐response profile of U937 cells to formyl peptide. Conclusions By facilitating the coupling of flow cytometers to other fluidics‐based analytical instruments, plug flow cytometry has extended analytical capabilities in cell adhesion and pharmacological characterization of receptor‐ligand interactions. Cytometry 43:211–216, 2001.This publication has 13 references indexed in Scilit:
- Expression of P-Selectin at Low Site Density Promotes Selective Attachment of Eosinophils Over NeutrophilsThe Journal of Immunology, 2000
- Plug flow cytometry: An automated coupling device for rapid sequential flow cytometric sample analysisCytometry, 1999
- Undifferentiated U937 cells transfected with chemoattractant receptors: a model system to investigate chemotactic mechanisms and receptor structure/function relationshipsJournal of Leukocyte Biology, 1997
- Threshold Levels of Fluid Shear Promote Leukocyte Adhesion through Selectins (CD62L,P,E)The Journal of cell biology, 1997
- Enhanced aggregation of human neutrophils by MnCl2 or DTT differentiates the roles of L-selectin and β2-integrinsJournal of Leukocyte Biology, 1996
- Use of four-colour flow cytometry to evaluate conjugate formation between human peripheral blood mononuclear cells and tumour target cellsCytometry, 1996
- P-selectin must extend a sufficient length from the plasma membrane to mediate rolling of neutrophils.The Journal of cell biology, 1995
- Quantitation and sorting of vitally stained natural killer cell‐target cell conjugates by dual beam flow cytometryCytometry, 1986
- A new generation of Ca2+ indicators with greatly improved fluorescence properties.Journal of Biological Chemistry, 1985
- The measurement of specific cell: Cell interactions by dual‐parameter flow cytometryCytometry, 1984