CT colonography with three-dimensional problem solving for detection of colonic polyps.
- 1 October 1998
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 171 (4), 989-995
- https://doi.org/10.2214/ajr.171.4.9762982
Abstract
We performed CT colonography in patients referred for conventional colonoscopy, interpreted the axial images, and used commercially available software to reconstruct endoluminal perspective views to differentiate polyps from folds. We prospectively examined 44 patients (27 men and 17 women; mean age, 58 years old) with CT colonography by interpreting the axial images and using three-dimensional rendering for problem solving only. The CT scans were interpreted by two radiologists who were unaware of patients' histories as revealed by colonoscopic findings. The findings on colonography were compared with those of conventional colonoscopy to determine sensitivity, specificity, time spent on interpretation, and confidence of interpretation. Colonoscopy showed normal findings in 28 patients and 22 polyps in the remaining 16 patients. Six polyps were 8 mm or larger, three were 5-7 mm, and 13 were 5 mm or smaller. The findings of the two observers revealed an overall sensitivity of 50% and 38%, respectively, and a specificity of 93% and 86%, respectively. Sensitivity for polyps larger than 8 mm was 83% and specificity was 100% for both observers. The average amount of time spent on interpretation was 28 min 30 sec (range, 14-65 min). Both observers used the endoluminal view for differentiating folds from polyps in 23 (52%) of 44 patients, which had only minimal impact on interpretation time. CT colonography can be performed and the images interpreted using currently available hardware and software by initially using the axial images to search for polyps of significant size. Endoluminal views should be used only when necessary to help distinguish normal folds from fixed raised lesions that are suggestive of polyps.Keywords
This publication has 10 references indexed in Scilit:
- Visualization of colorectal polyps with spiral CT colography: evaluation of processing parameters with perspective volume rendering.Radiology, 1997
- CT colonoscopy of colorectal neoplasms: two-dimensional and three-dimensional virtual-reality techniques with colonoscopic correlation.American Journal of Roentgenology, 1997
- Detection of colorectal polyps with CT colography: initial assessment of sensitivity and specificity.Radiology, 1997
- Virtual colonoscopy: what will the issues be?American Journal of Roentgenology, 1997
- Computed Tomographic Colonography (Virtual Colonoscopy): A New Method for Detecting Colorectal NeoplasmsEndoscopy, 1997
- Small simulated polyps in pig colon: sensitivity of CT virtual colography.Radiology, 1997
- Virtual ColonoscopyGastrointestinal Endoscopy Clinics of North America, 1997
- A Review of the Technical and Clinical Aspects of Virtual EndoscopyEndoscopy, 1996
- Colorectal polyp detection with CT colography: two- versus three-dimensional techniques. Work in progress.Radiology, 1996
- Use of air in double contrast barium enema — Is it still acceptable?Clinical Radiology, 1991