The Heart-Hemopump Interaction: A Study of Hemopump Flow as a Function of Cardiac Activity
- 1 May 1996
- journal article
- Published by Wiley in Artificial Organs
- Vol. 20 (5), 641-649
- https://doi.org/10.1111/j.1525-1594.1996.tb04496.x
Abstract
The Hemopump is a useful left ventricular assist device. Because it is a rotary blood pump, the pump performance is not constant and is dependent on the cardiac cycle. We measured the static flow delivered by the pump at varying pressure heads (ΔP) in a mock circulation. These data are compared to the pump performance in vivo. On the basis of these results, 5 sheep were instrumented for continuous Hemopump flow measurement as well as left ventricular and aortic pressure measurements. The Hemopump flow was relayed instantaneously to the pressure head. Low filling and ventricular failing (through intravenous administration of a beta-blocker) conditions were applied. The in vivo measured flows also are pressure head dependent, but the flow curve shows hysteresis resulting in a loop during each cardiac cycle. The in vivo peak flows (AP = 0) are similar to the in vitro data. The in vivo means flows (A 50 mm Hg) are similar to the in vitro data for the lower pump speeds but are less than that at the higher pump speeds (3.74 ± 0.55 L/min in vivo at Speed 7 versus 4.6 L/min in vitro). Low filling interrupts the AP-flow loop and reduces flow. In the failing ventricle, AP increases and flow is reduced. The cannula leaks and results in aortic insufficiency (0.36 ± 0.05 L/min) when the pump is turned off. Several conclusions have been drawn from these tests: Cardiac activity is beneficial for the pump performance as well as when the aortic pressure curve is nonpulsatile; the longer the systolic phase, the higher the pump flow; the pump should never be turned off in clinical use; and filling is important for the pump's performance.Keywords
This publication has 9 references indexed in Scilit:
- Left ventricular assistance with the transthoracic 24F Hemopump for recovery of the failing heartThe Annals of Thoracic Surgery, 1995
- Clinical use of the Hemopump cardiac assist system for circulatory supportThe Annals of Thoracic Surgery, 1995
- Postcardiotomy shock: Clinical evaluation of the BVS 5000 biventricular support systemThe Annals of Thoracic Surgery, 1993
- Left ventricular assist with an axial flow pump (Hemopump): Clinical applicationThe Annals of Thoracic Surgery, 1993
- Univentricular and biventricular thoratec VAD support as a bridge to transplantationThe Annals of Thoracic Surgery, 1993
- Postcardiotomy centrifugal mechanical ventricular supportThe Annals of Thoracic Surgery, 1992
- Ventricular assist devices for postcardiotomy cardiogenic shockThe Journal of Thoracic and Cardiovascular Surgery, 1992
- Bio-Medicus ventricular assist device for salvage of cardiac surgical patientsThe Annals of Thoracic Surgery, 1991
- Indications for the use of the HemopumpPublished by Springer Nature ,1991