Abstract
A convenient method for the accurate measurement of Doppler temperatures as a function of time has been developed and applied to the C Stellarator. General agreement between Doppler and other temperature measures has been found when the plasma is quiescent. Late in the period of plasma containment however, the ion‐Doppler temperatures begin to fall appreciably below the electron temperature. This is shown to be explainable in terms of an influx of cold gas which tends to overcome the heating by the electrons.Keywords
This publication has 6 references indexed in Scilit:
- Interpretation of Observed Impurity Radiation in a Discharge of the C-StellaratorPhysics of Fluids, 1964
- Equilibrium of a Current-Carrying Toroidal PlasmaPhysics of Fluids, 1963
- Preliminary Spectroscopic Results on a Very Long, High-Current, Magnetically Confined, Vacuum Carbon ArcJournal of the Optical Society of America, 1963
- Deviations from Kinetic Equilibrium in a Stellarator PlasmaPhysics of Fluids, 1962
- Stark Broadening of Neutral Helium Lines in a PlasmaPhysical Review B, 1962
- Stark Broadening of Hydrogen Lines in a PlasmaPhysical Review B, 1959