Apnea Testing in Brain Death
- 1 December 1986
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Internal Medicine
- Vol. 146 (12), 2385-2388
- https://doi.org/10.1001/archinte.1986.00360240117020
Abstract
• A standardized protocol was followed in 33 apneic oxygenation tests on 20 patients suspected of being brain dead. Spontaneous respiratory movements developed in just one patient; this patient was the only one who did not show electrocerebral silence on electroencephalography. Significant hypoxemia, hypotension, or cardiac arrhythmias were not encountered despite lung disease in 14 of our 20 patients. The apnea test protocol employed proved to be safe and sensitive. With a starting partial arterial carbon dioxide pressure greater than or equal to 36 mm Hg and a disconnection time from the ventilator of ten minutes in a normothermic patient (≥36.1°C [≥97°F]), the pressure threshold of 60 mm Hg should be reached in all patients. (Arch Intern Med 1986;146:2385-2388)This publication has 8 references indexed in Scilit:
- Modest Hypothermia Provides Partial Neuroprotection when Used for Immediate Resuscitation after Brain IschemiaPediatric Research, 1997
- Testing for apnea in suspected brain death: methods used by 129cliniciansNeurology, 1986
- Apnea testing to confirm brain death in childrenCritical Care Medicine, 1984
- The use of continuous flow of oxygen and PEEP during apnea in the diagnosis of brain deathIntensive Care Medicine, 1983
- Apnea Testing in Diagnosis of Brain DeathJournal of Neurosurgery, 1982
- Apnea testing in the diagnosis of brain deathJournal of Neurosurgery, 1981
- Bicarbonate and the regulation of ventilationThe American Journal of Medicine, 1974
- A METHOD FOR THE DETERMINATION OF THE VOLUME OF AIR IN THE LUNGS: MEASUREMENTS IN CHRONIC PULMONARY EMPHYSEMA*Journal of Clinical Investigation, 1961