Solid-Phase Microextraction for the Analysis of Human Breath
- 1 February 1997
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (4), 587-596
- https://doi.org/10.1021/ac960749l
Abstract
Solid-phase microextraction (SPME) has been applied to the quantitative determination of ethanol, acetone, and isoprene in human breath. The method involves extraction and preconcentration with a fused silica fiber coated with a polymeric stationary phase, desorption at 200 °C, and assay by gas chromatography/mass spectrometry. Three different fiber coatings have been evaluated with regard to sensitivity, linear range, precision, and detection limits. Typical RSD values in the range 2%−6% could be obtained, depending on the fiber coating and the compound investigated. The calibration curves for the compounds are reproducible and linear over the concentration ranges found in human breath samples. The method is capable of detecting concentrations of acetone and isoprene reported for healthy subjects. The influence of temperature and humidity on the extraction process has been studied in detail. A linear relationship between log K versus 1/T allows the calibration of the method for any given temperature. The device is portable, economical, and easy to use in patient sampling.Keywords
This publication has 15 references indexed in Scilit:
- Determination of isoprene in human breath by thermal desorption gas chromatography with ultraviolet detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1995
- Analysis of Environmental Air Samples by Solid-Phase Microextraction and Gas Chromatography/Ion Trap Mass SpectrometryEnvironmental Science & Technology, 1995
- Practical HPLC Method DevelopmentAnalytical Chemistry, 1994
- Application of thermal desorption to the biological monitoring of organic compounds in exhaled breathJournal of Chromatography A, 1993
- Dynamics of organic compound extraction from water using liquid-coated fused silica fibersAnalytical Chemistry, 1992
- High breath pentane concentrations during acute myocardial infarctionThe Lancet, 1991
- Gas chromatographic analysis of traces of light hydrocarbons. A review of different systems in practiceJournal of High Resolution Chromatography, 1989
- Detection of endogenous acetone in normal human breathJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- Ethane exhalation as an index of in vivo lipid peroxidation: Concentrating ethane from a breath collection chamberAnalytical Biochemistry, 1982
- Characterization of Human Expired Air: A Promising Investigative and Diagnostic TechniqueJournal of Chromatographic Science, 1977