Subacute Thrombosis and Vascular Injury Resulting From Slotted-Tube Nitinol and Stainless Steel Stents in a Rabbit Carotid Artery Model
- 1 October 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 94 (7), 1733-1740
- https://doi.org/10.1161/01.cir.94.7.1733
Abstract
Background Our objectives were to quantify the thrombogenicity and extent of vascular injury created by slotted-tube geometry stainless steel and nitinol coronary stents in a rabbit carotid artery model. Methods and Results Stents were implanted in rabbit right carotid arteries without antiplatelet therapy. Stainless steel stents were implanted for 4 days while nitinol stents were placed for 4 and 14 days (n=8, 8, and 6, respectively). Stent thrombosis was assessed by thrombus weight, grading thrombus encroachment of the lumen, and by blood flow in the stented and contralateral arteries. Stainless steel stents at 4 days contained more thrombus than 4- and 14-day nitinol stents (20.0±5.9 versus 2.5±0.6 and 2.7±0.3 mg, respectively; P<.000001). Stainless steel stents were more often occluded by thrombus (6 of 8) or contained more subocclusive thrombus (2 of 8) than nitinol stents (0 of 14, P<.002). Resting blood flow was reduced in arteries with stainless steel stents compared with 4- and 14-day nitinol stents (1.5±2.8 versus 24.0±2.0 and 25.5±1.9 mL/min, respectively, P<.000001). Stainless steel stents were less uniformly expanded, had deeper strut penetration into the vascular wall, and were associated with more extensive medial smooth muscle cell necrosis. There were strong correlations (r=.77 to .95) between variables of thrombosis extent (thrombus weight and grade) and histologically determined vascular injury (strut penetration and medial necrosis). Conclusions Slotted-tube stainless steel stents were more thrombogenic and created more extensive vascular injury than nitinol stents in a rabbit carotid artery model. The mechanisms underlying these differences probably are related to metallurgic and design geometry properties of the two stent types.Keywords
This publication has 23 references indexed in Scilit:
- 741-2 Full Antiplatelet Therapy without Anticoagulation After Coronary StentingJournal of the American College of Cardiology, 1995
- 741-1 Clinical Experience with Heparin-Coated Stents–The Benestent II Pilot Phase 1Journal of the American College of Cardiology, 1995
- Long-term angiographic and clinical outcome after implantation of a ballon-expandable stent in the native coronary circulationJournal of the American College of Cardiology, 1994
- Ticlopidine and subcutaneous heparin as an alternative regimen following coronary stentingCatheterization and Cardiovascular Diagnosis, 1994
- Implantation and recovery of temporary metallic stents in canine coronary arteriesJournal of the American College of Cardiology, 1993
- Multicenter investigation of coronary stenting to treat acute or threatened closure after percutaneous transluminal coronary angioplasty: Clinical and angiographic outcomesJournal of the American College of Cardiology, 1993
- Intracoronary stenting compared with conventional therapy for abrupt vessel closure complicating coronary angioplasty. A matched case-control studyJournal of the American College of Cardiology, 1993
- Thrombosis of a flexible coil coronary stent: Frequency, predictors and clinical outcomeJournal of the American College of Cardiology, 1993
- The role of von Willebrand factor and fibrinogen in platelet aggregation under varying shear stress.Journal of Clinical Investigation, 1991
- Shape-Memory AlloysScientific American, 1979