Hepatocellular carcinoma: Detection with diffusion-weighted versus contrast-enhanced magnetic resonance imaging in pretransplant patients
Open Access
- 28 February 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Hepatology
- Vol. 56 (1), 140-148
- https://doi.org/10.1002/hep.25681
Abstract
This study evaluates the performance of diffusion-weighted magnetic resonance imaging (DWI) for the detection of hepatocellular carcinoma (HCC) in pre–liver transplantation patients, compared and combined with contrast-enhanced T1-weighted imaging (CET1WI), using liver explant as the standard of reference. We included 52 patients with cirrhosis (40 men, 12 women; mean age, 56 years) who underwent DWI and CET1WI within 90 days of liver transplantation. Magnetic resonance images were analyzed for HCC detection in three separate sessions by two independent observers: DWI images (DW-set), CET1WI (CE-set), and all images together (All-set). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), per-patient accuracy, and per-lesion PPV were calculated for each image set. A total of 72 HCCs were present in 33 patients at explant (mean size, 1.5 cm [range, 0.3-6.2 cm]). Per-patient sensitivity and NPV of CE-set were significantly higher than those of DW-set when using pooled data between observers (P = 0.02 and 0.03, respectively), whereas specificity, PPV, and accuracy were equivalent. Per-lesion sensitivity was significantly higher for CE-set versus DW-set (59.0% versus 43.8%; P = 0.008, pooled data from two observers). When stratified by lesion size, the difference was significant only for lesions with a size between 1 and 2 cm (42.0% for DW-set versus 74.0% for CE-set; P = 0.001). The addition of DWI to CET1WI improved sensitivity for the more experienced observer. Conclusion: DWI is outperformed by CET1WI for detection of HCC, but represents a reasonable alternative to CET1WI for detection of HCC with a size above 2 cm. The addition of DWI to CET1WI slightly increases the detection rate. (HEPATOLOGY 2012;56:140–148)Keywords
This publication has 33 references indexed in Scilit:
- Detection of hepatocellular carcinoma (HCC) using super paramagnetic iron oxide (SPIO)‐enhanced MRI: Added value of diffusion‐weighted imaging (DWI)Journal of Magnetic Resonance Imaging, 2010
- Diffusion‐weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitionsJournal of Magnetic Resonance Imaging, 2009
- Added value of breathhold diffusion‐weighted MRI in detection of small hepatocellular carcinoma lesions compared with dynamic contrast‐enhanced MRI alone using receiver operating characteristic curve analysisJournal of Magnetic Resonance Imaging, 2009
- Receiver Operating Characteristic Analysis of Diffusion-Weighted Magnetic Resonance Imaging in Differentiating Hepatic Hemangioma From Other Hypervascular Liver LesionsJournal of Computer Assisted Tomography, 2008
- Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shotT2weighted turbo spin echo techniquesThe British Journal of Radiology, 2007
- Can a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging sequence with sensitivity encoding replace the respiratory‐triggered turbo spin‐echo sequence for the liver? an optimization and feasibility studyJournal of Magnetic Resonance Imaging, 2005
- Mri Angiography Is Superior to Helical Ct for Detection of Hcc Prior to Liver Transplantation: An Explant CorrelationHepatology, 2003
- Transplantation for hepatocellular carcinoma and cirrhosis: Sensitivity of magnetic resonance imagingLiver Transplantation, 2002
- Focal lesions in cirrhotic explant livers: Pathological evaluation and accuracy of pretransplantation imaging examinationsLiver Transplantation, 2002
- Terminology of nodular hepatocellular lesionsHepatology, 1995