Computed and conventional arthrotomography of the glenohumeral joint: normal anatomy and clinical experience.

Abstract
The glenohumeral joint was studied in 25 cadavers and 136 patients using computed arthrotomography (CAT) and conventional arthrotomography (AT) to assess shoulder instability. Cadaver shoulders were injected with air or latex, sectioned with a band saw, and normal articular anatomy outlined. CAT was performed in 81 patients and characterized the glenoid labrum as normal, abnormal, or detached in 38 of the 44 patients who had surgery or arthroscopy (sensitivity, 96% accuracy, 86%). Hill-Sachs defects were seen in 20 out of 29 patients with anterior labral abnormalities, while bicipital tendon abnormalities were evident on CAT in 6. Of 55 patients who had AT, the status of the labrum was clarified in 13 of the 16 patients who had surgery or arthroscopy (sensitivity, 86%; accuracy, 81%). Both methods can characterize the labrum; however, CAT is more comprehensive and appears ideal for both detection of Hill-Sachs defects and imaging the bicipital tendon. CAT requires less technical expertise and radiation than AT and is tolerated better by patients in pain.