Abstract
The theory of a method to measure electrical ground constants by mutual coupling of loops is outlined. Curves are given in parametric form showing the dependence of the mutual impedance on conductivity, dielectric constant, frequency, and separation. An expression is derived in the appendix for the field of a circular wire loop laid on a homogeneous conducting ground.