Decay Times of Commercial Organic Scintillators
- 1 June 1966
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 13 (3), 153-158
- https://doi.org/10.1109/tns.1966.4324093
Abstract
Response curves showing both short and long decay components are presented for fifteen commercially-available scintillators. Scintillator time-response functions for detection of 1.114-Mev gamma radiation (Zn-65) were measured over a range of three decades by employing a delayed coincidence technique. The apparatus, which was described in a previous paper, measures time intervals between the start of a gamma-induced scintillation event and the detection of a single visible photon. The region of the decay curve between 70 percent and 7 percent of the peak value is found to be very nearly exponential for most scintillators. The decay time for this region was determined for each scintillator to an accuracy of ±0.1 nanosecond.Keywords
This publication has 6 references indexed in Scilit:
- Apparatus for Precise Measurement of Scintillator Decay TimesIEEE Transactions on Nuclear Science, 1965
- Prepulses in photomultipliersNuclear Instruments and Methods, 1964
- Analyse par echantillonnage sur photons individuels des liquides fluorescents dans le domaine de la sub-nanosecondeNuclear Instruments and Methods, 1964
- FLUORESCENCE DECAY TIME MEASUREMENTS OF ORGANIC SCINTILLATORSCanadian Journal of Physics, 1962
- Measurement of the Time Dependence of Scintillation Intensity by a Delayed-Coincidence MethodReview of Scientific Instruments, 1961
- Measurements of Scintillation LifetimesReview of Scientific Instruments, 1953