The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.
- 1 June 1993
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 75 (6), 825-834
- https://doi.org/10.2106/00004623-199306000-00004
Abstract
We investigated the relationship between the toxic effects of metal wear particles and their ability to stimulate the release of inflammatory mediators implicated in bone resorption. In vitro studies were carried out with use of rat peritoneal macrophages, which were exposed to either cobalt-chromium-alloy or titanium-aluminum-vanadium particles, milled from the metal components of hip prostheses. The particles were in the size-range of, and at concentrations similar to, those found in the tissues surrounding failed prostheses in humans. The titanium-aluminum-vanadium particles showed little toxicity even at high concentrations, while the cobalt-chromium particles were very toxic. The titanium-aluminum-vanadium particles induced significantly more release of prostaglandin E2 than did the cobalt-chromium particles, and this was true for a wide range of concentrations. Exposure to titanium-aluminum-vanadium increased the release of prostaglandin E2, interleukin-1, tumor necrosis factor, and interleukin-6. In contrast, exposure to cobalt-chromium particles was associated with a decreased release of prostaglandin E2 and interleukin-6, and it had little effect on the release of interleukin-1 and tumor necrosis factor.This publication has 22 references indexed in Scilit:
- Polyethylene wear in knee arthroplastyActa Orthopaedica, 1992
- Resorption of bone by inflammatory cells derived from the joint capsule of hip arthroplastiesThe Journal of Bone and Joint Surgery. British volume, 1992
- Interleukin‐6 production by human gingival fibroblastsJournal of Periodontal Research, 1991
- Macrophage exposure to polymethyl methacrylate leads to mediator release and injuryJournal of Orthopaedic Research, 1991
- Cloning of human tumor necrosis factor (TNF) receptor cDNA and expression of recombinant soluble TNF-binding protein.Proceedings of the National Academy of Sciences, 1990
- Interleukin-1 and Its Biologically Related CytokinesAdvances in Immunology, 1989
- Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis.Journal of Bone and Joint Surgery, 1988
- Formation of a synovial‐like membrane at the bone‐cement interface: Its role in bone resorption and implant loosening after total hip replacementArthritis & Rheumatism, 1986
- EFFECTS OF COBALT‐CHROME ALLOY WEAR PARTICLES ON THE MORPHOLOGY, VIABILITY AND PHAGOCYTIC ACTIVITY OF MURINE MACROPHAGES IN VITROImmunology & Cell Biology, 1983
- Determination of Cell ViabilityExperimental Biology and Medicine, 1958