Abstract
The measurement of heart rate during exercise in the horse has been recommended as a means of prescribing work effort, monitoring the changes in aerobic capacity during training and as part of the clinical examination of the performance horse. The accuracy of four heart rate meters (PEH 100, PU 10, HR 14 and HRM-7) was assessed by comparison with heart rate determined by simultaneous telemetry electrocardiography (ECG) using a rapid incremental exercise test on a treadmill. Heart rate displayed by all four meters showed significant correlations with the ECG heart rate, but only two meters (PEH 100 and HRM-7) had correlation coefficients of 0.98 or greater.