Recombinant DNA derived monomeric insulin analogue: comparison with soluble human insulin in normal subjects.
- 12 November 1988
- Vol. 297 (6658), 1236-1239
- https://doi.org/10.1136/bmj.297.6658.1236
Abstract
OBJECTIVE--To compare the rate of absorption from subcutaneous tissue and the resulting hypoglycaemic effect of iodine-125 labelled soluble human insulin and a monomeric insulin analogue derived by recombinant DNA technology. DESIGN--Single blind randomised comparison of equimolar doses of 125I labelled soluble human insulin and insulin analogue. SETTING--Study in normal people at a diabetes research unit and a university department of medical physics. SUBJECTS--Seven healthy male volunteers aged 20-39 not receiving any other drugs. INTERVENTIONS--After an overnight fast and a basal period of one hour two doses (0.05 and 0.1 U/kg) of 125I labelled soluble human insulin and insulin analogue were injected subcutaneously into the anterior abdominal wall on four separate days. END POINT--To find a fast acting insulin for meal related requirements in insulin dependent diabetics. MEASUREMENTS and main results--Residual radioactivity at the injection site was measured continuously for the first two hours after injection of the 125I labelled preparations and thereafter for five minutes simultaneously with blood sampling. Frequent venous blood samples were obtained over six hours for determination of plasma immunoreactive insulin, insulin analogue, glucose, and glucagon values. Time to 50% of initial radioactivity at the injection site for the insulin analogue compared with soluble insulin was 61 v 135 minutes (p less than 0.05) with 0.05 U/kg and 67 v 145 minutes (p less than 0.001) with 0.1 U/kg. Concentrations in plasma increased faster after the insulin analogue compared with soluble insulin, resulting in higher plasma concentrations between 10 and 150 minutes (0.001 less than p less than 0.05) after 0.05 U/kg and between 40 and 360 minutes (0.001 less than p less than 0.05) after 0.1 U/kg. The hypoglycaemic response to insulin analogue was a plasma glucose nadir at 60 minutes with both doses compared with 90 and 120 minutes with soluble insulin at 0.5 and 0.1 U/kg respectively. The response of glucagon substantiated the earlier and more dramatic hypoglycaemic effect with the insulin analogue. CONCLUSIONS--The much faster absorption from subcutaneous tissue of the disubstituted monomeric insulin analogue compared with soluble insulin suggests that the analogue may be a potential candidate for rapid insulin delivery after subcutaneous bolus injection.This publication has 20 references indexed in Scilit:
- Insulin bolus given by sprinkler needle: effect on absorption and glycaemic response to a meal.BMJ, 1987
- Dissociation of Insulin Absorption and Blood Flow During Massage of a Subcutaneous Injection SiteDiabetes Care, 1986
- Comparison of Plasma Insulin Profiles After Subcutaneous Administration of Insulin by Jet Spray and Conventional Needle Injection in Patients With Insulin-Dependent Diabetes MellitusMayo Clinic Proceedings, 1984
- Plasma Free Insulin Profiles After Administration of Insulin by Jet and Conventional Syringe InjectionDiabetes Care, 1981
- Factors Influencing the Absorption, Serum Insulin Concentration, and Blood Glucose Responses After Injections of Regular Insulin and Various Insulin MixturesDiabetes Care, 1981
- “Normal” Insulin Secretion: The Goal of Artificial Insulin Delivery Systems?Diabetes Care, 1980
- Timing of pre-breakfast insulin injection and postprandial metabolic control in diabetic childrenBMJ, 1980
- Normalization of Plasma Insulin Profiles in Diabetic Subjects with Programmed Insulin DeliveryDiabetes Care, 1980
- Postprandial plasma glucose, insulin, glucagon and triglyceride responses to a standard diet in normal subjectsDiabetologia, 1976
- Determination of total serum insulin (IRI) in insulin-treated diabetic patientsDiabetologia, 1972