Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR
Open Access
- 23 April 1999
- journal article
- Published by Springer Nature in British Journal of Cancer
- Vol. 80 (5-6), 883-891
- https://doi.org/10.1038/sj.bjc.6690436
Abstract
In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-1 transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-1 measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-1 (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1–3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively. MART-1 PCR had a better performance than tyrosinase PCR. Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1–4 times). When applying real-time quantitative PCR for tyrosinase and MART-1, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results.Keywords
This publication has 34 references indexed in Scilit:
- RT-PCR for Tyrosinase-mRNA-Positive Cells in Peripheral Blood: Evaluation Strategy and Correlation with Known Prognostic Markers in 123 Melanoma PatientsJournal of Investigative Dermatology, 1998
- The Analysis of Tyrosinase-Specific mRNA in Blood Samples of Melanoma Patients by RT-PCR Is Not a Useful Test for Metastic Tumor ProgressionJournal of Investigative Dermatology, 1997
- A novel method for real time quantitative RT-PCR.Genome Research, 1996
- Real time quantitative PCR.Genome Research, 1996
- Peripheral Blood Tyrosinase Messenger RNA Detection and Survival in Malignant MelanomaJNCI Journal of the National Cancer Institute, 1996
- Polymerase Chain Reaction for Detection of Melanoma in Peripheral Blood: Too Early to Assess Clinical ValueJNCI Journal of the National Cancer Institute, 1996
- Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization.Genome Research, 1995
- Detection of Residual Tumor Cells in Patients with Malignant Melanoma Responding to ImmunotherapyJournal of Immunotherapy, 1994
- Hematogenous Spread of Malignant Melanoma Cells in Different Stages of DiseaseJournal of Investigative Dermatology, 1993
- Detection of melanoma cells in peripheral blood by means of reverse transcriptase and polymerase chain reactionThe Lancet, 1991