‘Zone model’ as an explanation for signal behaviour and non-spectral interferences in inductively coupled plasma mass spectrometry
- 1 January 1993
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 8 (3), 433-438
- https://doi.org/10.1039/ja9930800433
Abstract
The zone model is a simplified representation of the plasma, resulting from the findings of an optimization study for a VG PlasmaQuad PQ1 inductively coupled plasma (ICP) mass spectrometer (VG Elemental, Winsford, Cheshire, UK). According to this model, for every nuclide there is a zone in the central channel of the ICP, where a maximum density of singly charged ions occurs. The position of such a zone of maximum M+ density is a function of the mass number of the nuclide and the zone can undergo a spatial displacement under the influence of an alteration of an instrumental parameter or the introduction of a different matrix. This representation not only enables an explanation of a large number of observations from the optimization study, but also allows an understanding of why both matrix induced signal suppression and enhancement were observed, why for a given matrix the extent to which the signal intensities were altered differed from day to day and finally why the extent to which a signal is influenced by the matrix was seen to be a function of the mass number of the corresponding nuclide. Although the zone model might not completely reflect the genuine physical reality in all its facets, it provides a phenomenological model for the variation of ion signals with mass number, operating parameters and matrix composition.Keywords
This publication has 24 references indexed in Scilit:
- The use of internal standards in ICP-MSTalanta, 1992
- Study of the intensity of M+, M2+ and MO+ signals in ICP-MS as a function of instrumental parametersMicrochimica Acta, 1992
- Comparison of center-tapped and inverted load-coil geometries for inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Effects of sampler-skimmer separation in inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1990
- Investigation of Experimental Parameters with a Quadrupole ICP/MSApplied Spectroscopy, 1987
- System optimisation and the effect on polyatomic, oxide and doubly charged ion response of a commercial inductively coupled plasma mass spectrometry instrumentJournal of Analytical Atomic Spectrometry, 1987
- Oxide, Hydroxide, and Doubly Charged Analyte Species in Inductively Coupled Plasma/Mass SpectrometryApplied Spectroscopy, 1986
- Optimisation in inductively coupled plasma mass spectrometryThe Analyst, 1986
- The effect of plasma operating parameters on analyte signals in inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1985
- Analyte ionization in the inductively coupled plasmaSpectrochimica Acta Part B: Atomic Spectroscopy, 1985