Improved Timing with NaI(Tl)
- 1 June 1966
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 13 (3), 140-147
- https://doi.org/10.1109/tns.1966.4324091
Abstract
By timing on the earliest component of the anode current pulse of the photomultiplier, the time resolution obtained with NaI(TI) at 300°K can be made somewhat superior to that reported for pure NaI at 77°K. For example, the time distribution for x rays (31. 6 keV) relative to the conversion electrons from a Cs137 source, shows a full width at half maximum of 1.6 nsec and a slope corresponding to a half life T4324091 = 0.63 nsec. This implies that τ /R is much smaller than commonly believed, where τ is the mean life of the scintillation and R is the average number of photoelectrons per event. This small value is not due to a small τ because only the usual slow component is observed when the shape of the scintillation is measured by a probability technique. Therefore R must be larger than expected; the observed time resolution requires at least 8.7 photoelectrons/ keV. This is consistent with the value 9.3 p.e./ keV inferred from the pulse-height resolution obtained with artificial light pulses which are equivalent in amplitude to a 662-keV event in NaI(Tl). It is also consistent with the value (9. 1 p.e./keV) obtained by combining the absolute efficiency of NaI(Tl) measured by Van Sciver and Bogart with the quantum efficiency that RCA lists for the bi-alkali photocathode.Keywords
This publication has 11 references indexed in Scilit:
- Zeitauflösungseigenschaften von NaJ-SzintillatorenNuclear Instruments and Methods, 1965
- Revised theory of time resolution in scintillation countersNuclear Instruments and Methods, 1964
- A Versatile Solid-State Time-to-Pulse-Height ConverterIEEE Transactions on Nuclear Science, 1964
- Role of the tallium dimer in the NaI(Tl) scintillation processPhysics Letters, 1964
- A survey of the latest developments in delayed coincidence measurementsNuclear Instruments and Methods, 1963
- Neutron detection with glass scintillatorsNuclear Instruments and Methods, 1962
- An analytic treatment for scintillation counter time resolution functionsNuclear Instruments and Methods, 1962
- Measurements of instrumental time delay and resolution in a fast coincidence systemNuclear Instruments and Methods, 1961
- Measurement of the Time Dependence of Scintillation Intensity by a Delayed-Coincidence MethodReview of Scientific Instruments, 1961
- Fluorescent Response of NaI (Tl) to Nuclear RadiationsPhysical Review B, 1954