Immobilization of binding proteins on nonporous supports
- 1 July 1991
- journal article
- research article
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 30 (1), 83-98
- https://doi.org/10.1007/bf02922025
Abstract
Four different nonporous particulate materials, nylon, polystyrene, soda-lime silicate glass, and fused silica glass, have been evaluated for their appropriateness as immobilization supports for immuno-globulins. A method of protein quantitation that is usually applied to solutions, the bicinchoninic acid (BCA) assay, was used successfully to directly measure ng amounts of protein immobilized on the supports. Two proteins, a monoclonal antibody to theophylline and the biotin binding protein avidin, were studied. Radioactive theophylline and radioactive biotin were used to measure the activity of the immobilized protein. Ligand binding capacity per mm2 of support was measured as a function of amount of protein immobilized. By measuring both the amount of protein immobilized and its ligand binding capacity, we have determined that antitheophylline antibody adsorbed on polystyrene balls loses almost 90% of its binding activity after 65 h, although little protein is lost from the balls over this time. Avidin retains nearly full activity for biotin on polystyrene. The binding activity of biotinyl-antibody conjugate immobilized on avidin-adsorbed polystyrene is stable, even when stored for over 22 wk. Antibody covalently immobilized on soda-lime silicate glass beads retains its binding activity over long-term storage, although only 0.1 mol of3H-theophylline bind per mol of immobilized antibody. Using fused silica glass particles as the solid support, the same antibody binds approx 0.6 mol of ligand per mol of immobilized antibody protein. The structural “softness” of the immunoglobulin requires that interaction with the surface be prevented in order to maintain activity.This publication has 25 references indexed in Scilit:
- Models of protein adsorption on solid surfacesPublished by Springer Nature ,2007
- Radiometric and fluorimetric determination of aminosilanes and protein covalently bound to thermally pretreated glass substratesAnalytica Chimica Acta, 1990
- Assessment of coating-efficiency in ELISA plates by direct protein determinationJournal of Immunological Methods, 1986
- Application of solid-phase antibodies to radioimmunoassay Evaluation of two polymeric microparticles, Dynospheres and nylon, activated by carbonyldiimidazole or tresyl chlorideJournal of Immunological Methods, 1986
- Adsorption of proteins from solution at the solid-liquid interfaceAdvances in Colloid and Interface Science, 1986
- Immobilisation of Antibodies and Antigens on Macro Solid Phases — A Comparison Between Adsorptive and Covalent Binding. A critical study of macro solid phases for use in immunoassay systems, Part Icclm, 1983
- Chromatographic properties of silica-immobilized antibodiesAnalytical Chemistry, 1980
- Immobilization of antibodies on nylon for use in enzyme-linked immunoassayJournal of Immunological Methods, 1980
- Trypsin and Papain Covalently Coupled to Porous Glass: Preparation and CharacterizationScience, 1969
- Surface deactivation of porous glass membranesJournal of Biomedical Materials Research, 1969