Exploiting the complementary nature of LC/MALDI/MS/MS and LC/ESI/MS/MS for increased proteome coverage
- 1 September 2003
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 14 (9), 971-979
- https://doi.org/10.1016/s1044-0305(03)00209-5
Abstract
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.Keywords
This publication has 21 references indexed in Scilit:
- Comprehensive proteomic analysis of the human spliceosomeNature, 2002
- Comparison of three directly coupled HPLC MS/MS strategies for identification of proteins from complex mixtures: single-dimension LC-MS/MS, 2-phase MudPIT, and 3-phase MudPITInternational Journal of Mass Spectrometry, 2002
- The Large Subunit of the Mammalian Mitochondrial RibosomeJournal of Biological Chemistry, 2001
- Automated LC–LC–MS–MS platform using binary ion-exchange and gradient reversed-phase chromatography for improved proteomic analysesJournal of Chromatography B: Biomedical Sciences and Applications, 2001
- A Proteomics Approach to the Identification of Mammalian Mitochondrial Small Subunit Ribosomal ProteinsJournal of Biological Chemistry, 2000
- Comprehensive Two-Dimensional High-Performance Liquid Chromatography for the Isolation of Overexpressed Proteins and Proteome MappingAnalytical Biochemistry, 1998
- Two-Dimensional SEC/RPLC Coupled to Mass Spectrometry for the Analysis of PeptidesAnalytical Chemistry, 1997
- Direct Analysis and Identification of Proteins in Mixtures by LC/MS/MS and Database Searching at the Low-Femtomole LevelAnalytical Chemistry, 1997
- Protein sequence and structural studies employing matrix-assisted laser desorption ionization-high energy collision-induced dissociationInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Search of sequence databases with uninterpreted high-energy collision-induced dissociation spectra of peptidesJournal of the American Society for Mass Spectrometry, 1996