Bedside Diagnostic Blood Testing
- 17 July 1991
- journal article
- research article
- Published by American Medical Association (AMA)
- Vol. 266 (3), 382-389
- https://doi.org/10.1001/jama.1991.03470030082028
Abstract
Objective. —Bedside diagnostic testing utilizing microchemistry instruments potentially offers physicians the opportunity to evaluate urgent blood test results rapidly and reliably using only drops (250 μL) of whole blood. The use of microchemistry technology may also represent an essential component of a blood conservation program in acutely ill patients. We tested the hypothesis that a microchemistry instrument would have important advantages in the intensive care unit, including rapid turnaround time, decreased iatrogenic blood loss, and the provision of accurate analyte results. Design. —One-year prospective, random-sample comparative study. Setting. —A tertiary, acute care, 1000-bed university teaching hospital and a 450-bed university-affiliated community hospital. Patients. —Blood samples from 850 patients were analyzed. Results. —There were strong correlations (for pH,R2=.97; Pco2,R2=.97; Po2,R2=.99; sodium,R2=.83; potassium,R2=.94; chloride,R2=.90; glucose,R2=.98; and hematocrit,R2=.92) when paired samples were analyzed simultaneously in the laboratory comparing the microchemistry instrument and currently accepted clinical laboratory instruments. There were significant correlations (for pH,R2=.91; Pco2,R2=.94; Po2,R2=.97; sodium,R2=.91; potassium,R2=.86; chloride,R2=.91; ionized calcium,R2=.82; glucose,R2=.96; and hematocrit,R2=.75) but increased variability occurred in some analyte results when samples were first analyzed in the intensive care unit (using the microchemistry instrument) and then transported to the laboratory in the routine fashion for "stat" determinations. Conclusions. —The multichannel microchemistry instrument provided accurate analyte determinations when compared with accepted clinical laboratory instruments. Significant savings of time and blood were also realized by the use of a microchemistry instrument in the intensive care unit. Bedside microchemistry may provide clinically important advantages in emergency departments, operating rooms, and neonatal, pediatric, coronary, adult medical and surgical, trauma, and burn intensive care units. (JAMA. 1991;266:382-389)Keywords
This publication has 20 references indexed in Scilit:
- Evaluation of Bedside Testing Options for the Critical Care UnitChest, 1990
- Evaluation of a Blood Gas and Chemistry Monitor for Use during SurgeryAnesthesiology, 1989
- RAPID BEDSIDE ANALYSIS OF ARTERIAL BLOOD GASES AND ELECTROLYTES IMPROVES PATIENT CARE DURING AND AFTER CARDIAC SURGERYAnesthesiology, 1988
- Phlebotomy for Diagnostic Laboratory Tests in AdultsNew England Journal of Medicine, 1986
- Too much heparin: possible source of error in blood gas analysis.BMJ, 1983
- Variability of Arterial Blood Gas Values in Stable Patients in the ICUChest, 1983
- Blood gas analysis: effect of air bubbles in syringe and delay in estimation.BMJ, 1982
- Air bubbles and temperature effect on blood gas analysis.Journal of Clinical Pathology, 1980
- Pseudohyperkalemia Due to Release of Potassium from White Blood Cells during ClottingNew England Journal of Medicine, 1966
- Pseudohyperkalemia with ThrombocytosisNew England Journal of Medicine, 1962