Removal of local field gradient artifacts in T2*‐weighted images at high fields by gradient‐echo slice excitation profile imaging
- 1 March 1998
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 39 (3), 402-409
- https://doi.org/10.1002/mrm.1910390310
Abstract
Development of high magnetic field MRI techniques is hampered by the significant artifacts produced by B0 field inhomogeneities in the excited slices. A technique, gradient‐echo slice excitation profile imaging (GESEPI), is presented for recovering the signal lost caused by intravoxel phase dispersion in T2*‐weighted images. This technique superimposes an incremental gradient offset on the slice refocusing gradient to sample Jr‐space over the full range of spatial frequencies of the excitation profile. A third Fourier transform of the initial two‐dimensional image set generates an image set in which the artifacts produced by the low‐order B0 inhomogeneity field gradients in the sample are separated and removed from the high‐order microscopic field gradients responsible for T2* contrast. Application to high field brain imaging, at 3.0 T for human and at 9.4 T for immature rat imaging demonstrates the significant improvement in quality of the T2*‐weighted contrast images.Keywords
This publication has 16 references indexed in Scilit:
- Theory and application of static field inhomogeneity effects in gradient‐echo imagingJournal of Magnetic Resonance Imaging, 1997
- Multi‐gradient echo with susceptibility inhomogeneity compensation (MGESIC): Demonstration of fMRI in the olfactory cortex at 3.0 TMagnetic Resonance in Medicine, 1997
- Three‐dimensional mapping of the static magnetic field inside the human headMagnetic Resonance in Medicine, 1996
- Susceptibility Magnetic Resonance Imaging Using Spectral DecompositionMagnetic Resonance in Medicine, 1995
- Assessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 TeslaMagnetic Resonance in Medicine, 1994
- Assessment of Cerebral Blood Volume with Dynamic Susceptibility Contrast Enhanced Gradient-Echo ImagingJournal of Computer Assisted Tomography, 1994
- Reduction of susceptibility artifact in gradient‐echo imagingMagnetic Resonance in Medicine, 1992
- In vivo Quantitative characterization of trabecular bone by NMRMagnetic Resonance in Medicine, 1991
- Susceptibility artifacts in spin-echo and gradient-echo imagingJournal of Magnetic Resonance (1969), 1990
- Perfusion imaging with NMR contrast agentsMagnetic Resonance in Medicine, 1990