Electrocatalytic sulfite biosensor with human sulfite oxidase co-immobilized with cytochrome c in a polyelectrolyte-containing multilayer
Open Access
- 21 October 2008
- journal article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 393 (1), 225-233
- https://doi.org/10.1007/s00216-008-2432-y
Abstract
An efficient electrocatalytic biosensor for sulfite detection was developed by co-immobilizing sulfite oxidase and cytochrome c with polyaniline sulfonic acid in a layer-by-layer assembly. QCM, UV–Vis spectroscopy and cyclic voltammetry revealed increasing loading of electrochemically active protein with the formation of multilayers. The sensor operates reagentless at low working potential. A catalytic oxidation current was detected in the presence of sulfite at the modified gold electrode, polarized at +0.1 V (vs. Ag/AgCl 1 M KCl). The stability of the biosensor performance was characterized and optimized. A 17-bilayer electrode has a linear range between 1 and 60 µM sulfite with a sensitivity of 2.19 mA M−1 sulfite and a response time of 2 min. The electrode retained a stable response for 3 days with a serial reproducibility of 3.8% and lost 20% of sensitivity after 5 days of operation. It is possible to store the sensor in a dry state for more than 2 months. The multilayer electrode was used for determination of sulfite in unspiked and spiked samples of red and white wine. The recovery and the specificity of the signals were evaluated for each sample.Keywords
This publication has 35 references indexed in Scilit:
- Self-Assembly of S-Layer-Enveloped Cytochrome c Polyelectrolyte MultilayersLangmuir, 2008
- Electrocatalytically functional multilayer assembly of sulfite oxidase and cytochrome cSoft Matter, 2008
- Layer-by-Layer Arrangement by Protein−Protein Interaction of Sulfite Oxidase and Cytochrome c Catalyzing Oxidation of SulfiteJournal of the American Chemical Society, 2008
- Sulfite determination using sulfite oxidase biosensor based glassy carbon electrode coated with thin mercury filmFood Chemistry, 2007
- Determination of trace sulfite by direct and indirect methods using differential pulse polarographyAnalytica Chimica Acta, 2007
- Electron Transfer in SAM/Cytochrome/Polyelectrolyte Hybrid Systems on Electrodes: A Time-Resolved Surface-Enhanced Resonance Raman StudyLangmuir, 2007
- Determination of sulfite in beer samples using an amperometric fill and flow channel biosensor employing sulfite oxidaseAnalytica Chimica Acta, 2006
- A sulfite biosensor fabricated using electrodeposited polytyramine: application to wine analysisThe Analyst, 1999
- Use of tyrosinase for enzymatic elimination of acetaminophen interference in amperometric sensingAnalytica Chimica Acta, 1993
- Voltammetry of covalently immobilized cytochrome c on self-assembled monolayer electrodesLangmuir, 1992