Abstract
A CT scanner has been used to measure the electron density of a range of bone types in vivo. It is shown that there is a linear relationship between the CT number of bone and its electron density, which is expected theoretically if different bone types are treated as a variable mixture of osseous material and marrow. A method of calibrating and CT scanner using a simply prepared solution is proposed, which should enable electron densities of bone to be estimated from CT numbers with an accuracy of 5%.This publication has 17 references indexed in Scilit:
- Definitions of effective energy in computed tomographyPhysics in Medicine & Biology, 1981
- An accurate parametrisation of the X-ray attenuation coefficientPhysics in Medicine & Biology, 1980
- The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous mediaPhysics in Medicine & Biology, 1979
- The Equivalent Tissue-Air Ratio Method for Making Absorbed Dose Calculations in a Heterogeneous MediumRadiology, 1978
- A Quantitative Theory of the Hounsfield Unit and Its Application to Dual Energy ScanningJournal of Computer Assisted Tomography, 1977
- Corrections to absorbed dose calculations for tissue inhomogeneitiesMedical Physics, 1977
- The Use of CT Scanners in Megavoltage Photon-Beam Therapy PlanningRadiology, 1977
- Use of body scanner in radiotherapy treatment planningCancer, 1977
- Measurement of effective atomic number and electron density using an EMI scannerNeuroradiology, 1976
- Photon attenuation in computed tomographyMedical Physics, 1975