Measurement of Cerebral Blood Flow Using Bolus Inhalation of C15O2 and Positron Emission Tomography: Description of the Method and its Comparison with the C15O2 Continuous Inhalation Method
Open Access
- 1 June 1984
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 4 (2), 224-234
- https://doi.org/10.1038/jcbfm.1984.31
Abstract
This article describes a rapid method for the regional measurement of cerebral blood flow using a single breath of C15O2 and positron emission tomography. The technique is based on the bolus distribution principle and utilises a reference table for the calculation of flow. Seven subjects were studied using both this method and the C15O2 continuous inhalation steady-state technique. The single-breath method gave flow values 20% higher than those obtained using the steady-state method. A simulation study was performed in an attempt to define the reasons for the difference between the two techniques. Estimations were made of identified sources of error in the measurement of regional cerebral blood flow using the single-breath technique and compared with results from a similar study previously described for the steady-state technique. However, further comparative studies will be necessary to satisfactorily explain the difference between both techniques.Keywords
This publication has 12 references indexed in Scilit:
- Correction for the Presence of Intravascular Oxygen-15 in the Steady-State Technique for Measuring Regional Oxygen Extraction Ratio in the Brain: 1. Description of the MethodJournal of Cerebral Blood Flow & Metabolism, 1983
- A Statistical Study of the Steady State Technique for Measuring Regional Cerebral Blood Flow and Oxygen Utilisation Using 15OJournal of Computer Assisted Tomography, 1982
- Measurement of Local Blood Flow and Distribution Volume with Short-Lived Isotopes: A General Input TechniqueJournal of Cerebral Blood Flow & Metabolism, 1982
- A Simplified in vivo Autoradiographic Strategy for the Determination of Regional Cerebral Blood Flow by Positron Emission Tomography: Theoretical Considerations and Validation Studies in the RatJournal of Cerebral Blood Flow & Metabolism, 1982
- A New Journal and a New Society—Why?Journal of Cerebral Blood Flow & Metabolism, 1981
- Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission TomographyJournal of Computer Assisted Tomography, 1980
- Two Methods for Calculating Regional Cerebral Blood Flow from Emission Computed Tomography of Inert Gas ConcentrationsJournal of Computer Assisted Tomography, 1979
- Design and Performance Characteristics of a Positron Emission Computed Axial Tomograph--ECAT®-IIIEEE Transactions on Nuclear Science, 1979
- Transverse section imaging of mean clearance timePhysics in Medicine & Biology, 1978
- Dynamic Positron Emission Tomography for Study of Cerebral Hemodynamics in a Cross Section of the Head Using Positron-Emitting 68Ga-EDTA and 77KrJournal of Computer Assisted Tomography, 1977