Performance of presbyopia-correcting intraocular lenses in distance optical bench tests
- 1 January 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (1), 166-171
- https://doi.org/10.1016/j.jcrs.2008.10.026
Abstract
To compare the optical performance of 6 presbyopia-correcting intraocular lenses (IOLs) of different designs (accommodating or multifocal and aspheric or spheric). Alcon Laboratories, Inc., Fort Worth, Texas, USA. The optical performance of 6 IOLs were compared using modulation transfer function (MTF) and the United States Air Force 1951 Resolution Target (AFT) testing. The IOLs included 3 spheric designs (Crystalens AT-50SE, AcrySof ReSTOR SA60D3, and ReZoom NXG1) and 3 aspheric designs (AcrySof ReSTOR SN6AD3, Acri.Lisa 366D, and Tecnis ZM900). Tests were performed with a modified International Organization for Standardization (ISO) model eye with a 5.0 mm aperture at the distance focus. The ReSTOR aspheric IOL had the highest MTF values at all spatial frequencies, and the ReZoom IOL had the lowest MTF values at most spatial frequencies. The ReSTOR aspheric IOL produced the image with the highest resolution on the AFT test; the Tecnis and the ReZoom IOLs produced the images with the poorest resolution. The Acri.Lisa multifocal IOL was second to the ReSTOR aspheric IOL on the MTF test and had high resolution on the AFT test. The accommodating Crystalens performed poorly on the MTF test but had the second highest resolution on the AFT test. The AcrySof ReSTOR SN6AD3 aspheric IOL showed superior optical properties, demonstrated in MTF and AFT optical bench testing, among 6 presbyopia-correcting IOLs including the monofocal accommodating Crystalens. The Acri.Lisa IOL also performed well. The ReZoom IOL demonstrated the poorest overall optical quality.Keywords
This publication has 19 references indexed in Scilit:
- Intraocular lenses with surface aspherization: Interferometric studyJournal of Cataract & Refractive Surgery, 2007
- Higher-order aberrations from the internal optics of the eyeJournal of Cataract & Refractive Surgery, 2005
- Quality of vision after AMO Array multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2004
- Age-related changes in corneal and ocular higher-order wavefront aberrationsAmerican Journal of Ophthalmology, 2004
- Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parametersAlbrecht von Graefes Archiv für Ophthalmologie, 2001
- Subjective photic phenomena with refractive multifocal and monofocal intraocular lensesJournal of Cataract & Refractive Surgery, 2001
- Optical aberrations of the human cornea as a function of ageJournal of the Optical Society of America A, 2000
- Cataract extraction with multifocal intraocular lens implantation: Clinical, functional, and quality-of-life outcomesJournal of Cataract & Refractive Surgery, 2000
- Determining the imaging quality of intraocular lensesJournal of Cataract & Refractive Surgery, 1998
- Presbyopia and the optical changes in the human crystalline lens with ageVision Research, 1998