Segmental bioelectrical impedance analysis to assess perioperative fluid changes
- 1 July 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 28 (7), 2390-2396
- https://doi.org/10.1097/00003246-200007000-00034
Abstract
Perioperative fluid accumulation determination is a challenge for the clinician. Bioelectrical impedance analysis (BIA) is a noninvasive method based on the electrical properties of tissues, which can assess body fluid compartments. The study aimed at assessing their changes in three types of surgery (thoracic, abdominal, and intracranial) requiring various regimens of fluid administration. Prospective descriptive trial. A total of 26 patients scheduled for elective surgery were separated into three groups according to site of surgery: thoracic (n = 8), abdominal aortic (n = 8), and brain surgery (n = 10). University teaching hospital. None. Whole body, segmental (arm, trunk, and legs) BIA at multiple frequency (0.5, 50, 100 kHz) was used to assess perioperative fluid accumulation after surgery. The fluid balances were calculated from the charts. The patients were aged 62 ± 4 yrs. Fluid balances were 4.8 ± 1.0 L, 4.1 ± 0.5 L, and 1.9 ± 0.3 L, respectively, in the three groups. In trunk surgery patients, fluid accumulation was detected as a drop in impedance in the operated area at all frequencies. In the operated area, there was an expansion of both intra- and extracellular compartments. A reduction in high frequencies’ impedance in the legs was only detected after aortic surgery. Fluid accumulation and trunk impedance changes were strongly correlated. Neurosurgery only induced minor body fluid changes. Segmental BIA is able to detect and localize perioperative fluid accumulation. It may become a bedside tool to quantify and to localize fluid accumulation.Keywords
This publication has 16 references indexed in Scilit:
- Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedanceCritical Care Medicine, 1998
- Use of bioelectrical impedance analysis measurements in the clinical management of critical illnessThe American Journal of Clinical Nutrition, 1996
- Multifrequency bioelectrical impedance estimates the distribution of body waterJournal of Applied Physiology, 1995
- Segmental bioelectrical impedance analysis: theory and application of a new techniqueJournal of Applied Physiology, 1994
- Estimation of body composition from bioelectrical impedance of body segments: Comparison with dual-energy X-ray absorptiometryBritish Journal of Nutrition, 1993
- Whole-body and segmental bioelectrical-impedance analysis in patients with cirrhosis of the liver: changes after treatment of ascitesThe American Journal of Clinical Nutrition, 1992
- Estimation of extracellular and total body water by multiple-frequency bioelectrical-impedance measurementThe American Journal of Clinical Nutrition, 1991
- Assessment of changes in total body water in patients undergoing renal dialysis using bioelectrical impedance analysisClinical Nutrition, 1991
- Large capacity in man for effective plasma volume control in hypovolaemia via fluid transfer from tissue to bloodActa Physiologica Scandinavica, 1989
- Extracellular Fluid Deficit Following Operation and Its Correction with Ringerʼs LactateAnnals of Surgery, 1985