Application of orthogonal functions to correct for quadratic irrelevant absorption in spectrophotometric analysis
- 1 January 1973
- journal article
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 25 (1), 69-72
- https://doi.org/10.1111/j.2042-7158.1973.tb09118.x
Abstract
The seven-point correction method of Ashton and Tootill has been examined. The method is generalized for other groups of points from n = 5 to n = 14. Glenn's method of orthogonal functions proved to be suitable for assaying cyclandelate in the presence of interference with quadratic curvature.Keywords
This publication has 6 references indexed in Scilit:
- The Use of Orthogonal Functions to Correct for Irrelevant Absorption in Two Component Spectrophotometric AnalysisJournal of Pharmacy and Pharmacology, 1963
- NotesThe Analyst, 1961
- Determination of griseofulvin in fermentation samples. Appendix to part I: seven-point correction procedureThe Analyst, 1956
- Numerical CalculusPublished by Walter de Gruyter GmbH ,1949
- Photoelectric spectrophotometry applied to the analysis of mixtures, and vitamin A oilsThe Analyst, 1946
- Application of Infrared Spectroscopy to Industrial ResearchIndustrial & Engineering Chemistry Analytical Edition, 1941