Delta function convolution method (DFCM) for fluorescence decay experiments
- 1 January 1985
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 56 (1), 14-22
- https://doi.org/10.1063/1.1138457
Abstract
A rigorous and convenient method of correcting for the wavelength variation of the instrument response function in time correlated photon counting fluorescence decay measurements is described. The method involves convolution of a modified functional form F̃s of the physical model with a reference data set measured under identical conditions as the measurement of the sample. The method is completely general in that an appropriate functional form may be found for any physical model of the excited state decay process. The modified function includes a term which is a Dirac delta function and terms which give the correct decay times and preexponential values in which one is interested. None of the data is altered in any way, permitting correct statistical analysis of the fitting. The method is readily adaptable to standard deconvolution procedures. The paper describes the theory and application of the method together with fluorescence decay results obtained from measurements of a number of different samples including diphenylhexatriene, myoglobin, hemoglobin, 4′, 6-diamidine–2-phenylindole (DAPI), and lysine–trytophan–lysine.Keywords
This publication has 31 references indexed in Scilit:
- Excitation pulse-shape mimic technique for improving picosecond-laser-excited time-correlated single-photon counting deconvolutionsReview of Scientific Instruments, 1983
- Distortion of gaussian pulses by a diffraction gratingOptics Communications, 1982
- [17] Time-resolved fluorescence measurementsMethods in Enzymology, 1979
- Correction of instrumental time response variation with wavelength in fluorescence lifetime determinations in the ultraviolet regionReview of Scientific Instruments, 1977
- The deconvolution of photoluminescence dataThe Journal of Physical Chemistry, 1977
- Confidence in fluorescence lifetime determinations: a ratio correction for the photomultiplier time response with wavelengthCanadian Journal of Chemistry, 1976
- The use of standards in the analysis of fluorescence decay dataAnalytical Biochemistry, 1976
- Determination of ascorbic acid in foodstuffs, pharmaceuticals, and body fluids by liquid chromatography with electrochemical detectionAnalytical Chemistry, 1976
- Analysis of fluorescence decay curves by means of the Laplace transformationBiophysical Journal, 1975
- The wavelength dependence of the response of a pulse fluorometer using the single photoelectron counting methodReview of Scientific Instruments, 1974