Carotid Artery Stenting Protected With an Emboli Containment System
- 1 May 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Stroke
- Vol. 33 (5), 1308-1314
- https://doi.org/10.1161/01.str.0000013947.17575.b3
Abstract
Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire with a detachable adapter that inflates and deflates the distal temporary occlusion balloon. An aspiration catheter is used to remove trapped emboli after stenting and before occlusion balloon deflation. Seventy-five patients with severe internal carotid artery stenosis were treated with stents deployed with this cerebrovasculature protection system. All 75 patients (100%) had grossly visible particulate material aspirated, and all were treated successfully without major or minor stroke or death at 30 days. Preintervention stenosis was 81+/-10%, and residual stenosis was 5+/-7%. Nine patients (12%) had angiographic evidence of thrombus before intervention, but no patient had thrombus or vessel cutoff after the procedure. Four patients (5%) developed transient neurological symptoms during protection balloon occlusion, but symptoms resolved with balloon deflation. The 22 to 667 particles aspirated per patient ranged from 3.6 to 5262 microm in maximum diameter (mean, 203+/-256 microm). These particles included fibrous plaque debris, lipid or cholesterol vacuoles, and calcific plaque fragments. Protected carotid stenting was performed successfully and safely in this study early in the experience with cerebrovascular protection devices. Particulate emboli are frequent with stenting, and cerebral protection will likely be necessary to minimize stroke. Randomized trials comparing protected carotid stenting with endarterectomy are warranted.Keywords
This publication has 14 references indexed in Scilit:
- Carotid Stenting With Cerebral Protection: First Clinical Experience Using the PercuSurge GuardWire SystemJournal of Endovascular Surgery, 1999
- Microemboli detected by transcranial Doppler monitoring in patients during carotid angioplasty versus carotid endarterectomyCardiovascular Surgery, 1998
- Randomized study of carotid angioplasty and stenting versus carotid endarterectomy: a stopped trialJournal of Vascular Surgery, 1998
- Current global status of carotid artery stent placementCatheterization and Cardiovascular Diagnosis, 1998
- Endarterectomy for Asymptomatic Carotid Artery StenosisJAMA, 1995
- Carotid Endarterectomy and Prevention of Cerebral Ischemia in Symptomatic Carotid StenosisJAMA, 1991
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991
- MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosisThe Lancet, 1991
- Angioplasty-induced dissections in human iliac arteries: management with Palmaz balloon-expandable intraluminal stents.Radiology, 1990
- Placement of Balloon-expandable Intraluminal Stents in Iliac Arteries: First 171 ProceduresRadiology, 1990