Critical PQ Interval for the Appearance of Diastolic Mitral Regurgitation and Optimal PQ Interval in Patients Implanted with DDD Pacemakers
- 1 November 1994
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (11), 1989-1994
- https://doi.org/10.1111/j.1540-8159.1994.tb03786.x
Abstract
Diastolic mitral regurgitation (MR) may be induced by prolonging atrioventricular (AV) delay, and a significant negative correlation has been described between the critical PQ interval for the appearance of diastolic MR and pulmonary capillary wedge pressure (PCWP) in patients with DDD pacemakers. We report the relationship between the critical PQ interval for the appearance of diastolic MR and the optimal PQ interval in 11 patients (69.1 +/- 12.6 years). Cardiac output (CO) and PCWP were measured by Swan-Ganz catheter and transmitral blood flow was recorded by pulsed-Doppler echocardiography. AV delay was prolonged stepwise by 0.025 seconds starting from 0.065 seconds. The pacing rate was fixed at 70 beats/min. CO was highest when the PQ interval was 0.18 +/- 0.04 seconds. There was a significant positive correlation between the critical PQ interval for the appearance of diastolic MR and the PQ interval at which CO was the highest (r = 0.91, P < 0.01). The PQ interval at which CO was the highest was 0.02 +/- 0.02 seconds shorter than the critical PQ interval for the appearance of diastolic MR (P < 0.05). When the PQ interval was increased by 0.025 seconds from the critical PQ interval for the appearance of diastolic MR, CO decreased from 4.3 +/- 0.6 L/min to 4.1 +/- 0.6 L/min and PCWP increased from 7.5 +/- 6.4 mmHg to 8.5 +/- 7.3 mmHg (P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 12 references indexed in Scilit:
- Improvement of Cardiac Function in Patients with Severe Congestive Heart Failure and Coronary Artery Disease by Dual Chamber Pacing with Shortened AV DelayPacing and Clinical Electrophysiology, 1993
- Diastolic Mitral Regurgitation in Patients with First‐Degree Atrioventricular BlockPacing and Clinical Electrophysiology, 1992
- Comparison of Intrinsic Versus Paced Ventricular FunctionPacing and Clinical Electrophysiology, 1992
- Hemodynamic Effect of Physiological Dual Chamber Pacing in a Patient with End‐Stage Dilated Cardiomyopathy: A Case ReportPacing and Clinical Electrophysiology, 1991
- Effect of Short Atrioventricular Delay on Cardiac OutputPacing and Clinical Electrophysiology, 1990
- Usefulness of physiologic dual-chamber pacing in drug-resistant idiopathic dilated cardiomyopathyThe American Journal of Cardiology, 1990
- Detection of diastolic atrioventricular valvular regurgitation by “M-mode” color Doppler echocardiographyThe American Journal of Cardiology, 1989
- Diastolic mitral regurgitation in acute but not chronic aortic regurgitation: Implications regarding the mechanism of mitral closureAmerican Heart Journal, 1989
- The influence of atrial contraction and mitral valve mechanics on ventricular fillingAmerican Heart Journal, 1969
- Atriogenic Diastolic Reflux in Patients with Atrioventricular BlockCirculation, 1966