Off‐resonance spin locking for MR imaging
- 1 July 1994
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 32 (1), 43-51
- https://doi.org/10.1002/mrm.1910320107
Abstract
Off-resonance spin locking is investigated as a low power method for achieving low field spin-lattice relaxation contrast using high field clinical MR imaging systems (e.g., 1.5 tesla). Spin-lattice relaxation times and equilibrium magnetizations in the off-resonance rotating frame (T β) were measured for tissue-mimicking phantom materials as a function of the ratio of the amplitude to the resonance offset of the spin-locking pulse (f1/Δ). The phantom materials consisted of vegetable oil to simulate fat and two different gels containing 2% and 4% agar to simulate nonfatty tissues with different macromolecular compositions. These measurements were used to verify a signal strength equation for a multislice off-resonance spin-locking technique implemented on a clinical MR imaging system operating at 1.5 tesla. Although the oil showed little change in image contrast with increasing f1/Δ, the two gels demonstrated a strong variation which provided improved discrimination compared to T1-weighted imaging. Off-resonance spin locking is suggested as a method for improving delineation of breast lesions and a preliminary clinical example from a patient volunteer is presented.Keywords
This publication has 17 references indexed in Scilit:
- 1 /T1p and Low‐Field 1 / T1 of Tissue Water Protons Arise from Magnetization Transfer to Macromolecular Solid‐State Broadened LinesMagnetic Resonance in Medicine, 1992
- Magnetization transfer contrast in fat‐suppressed steady‐state three‐dimensional MR imagesMagnetic Resonance in Medicine, 1992
- Incorporation of magnetization transfer into the formalism for rotating-frame spin-lattice proton NMR relaxation in the presence of an off-resonance-irradiation fieldJournal of Magnetic Resonance (1969), 1991
- Low-contrast focal lesion detectability phantom for 1 H MR imagingMedical Physics, 1991
- A simple method for the restoration of signal polarity in multi‐image inversion recovery sequences for measuring T1Magnetic Resonance in Medicine, 1991
- Off-resonance rotating frame spin-lattice NMR relaxation studies of phosphorus metabolite rotational diffusion in bovine lens homogenatesBiochemistry, 1990
- Volume‐selective determination of the spin‐lattice relaxation time in the rotating frame, T1ρ, and T1ρ, imagingMagnetic Resonance in Medicine, 1989
- Spin locking for magnetic resonance imaging with application to human breastMagnetic Resonance in Medicine, 1989
- Efficient adiabatic fast passage for NMR population inversion in the presence of radiofrequency field inhomogeneity and frequency offsetsJournal of Magnetic Resonance (1969), 1986
- A pulsed NMR study of nuclear spin-lattice relaxation in the off resonance rotating frameJournal of Magnetic Resonance (1969), 1974