Soft Copy Display Requirements for Digital Mammography
- 15 December 2003
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 16 (3), 292-305
- https://doi.org/10.1007/s10278-003-1659-6
Abstract
One of the advantages of digital mammography is to display mammograms on softcopy (electronic displays). Softcopy display of mammography is challenging because of the spatial and contrast resolution demands present in mammograms. We have designed and developed a softcopy mammography display application, Mammoview, which is capable of allowing radiologists to read mammograms as quickly and as accurately as they can on film alternators. We review the studies using Mammoview to elucidate the requirements of a successful softcopy display station. The design and development of the Mammoview softcopy display station are described in this article, and results of several studies using Mammoview are reported, including subjective feedback from Radiological Society of North America (RSNA) conference demonstrations, and clinical studies measuring performance in terms of speed and accuracy. Additional analysis of user interactions and user feedback is used to study the successes and shortcomings of mammography display stations like Mammoview. Overall, radiologist readings using Mammoview have been shown to be as fast and as accurate as readings using mammography film alternators. However, certain parts of the softcopy interface were more successful than their film counterparts, whereas others were less successful. Data analysis of the recorded human-computer interactions for the softcopy component of the clinical trial indicate statistically significant correlations between the difference in review time of softcopy versus alternator readings and three factors: the number of interactions, the reader, and the size of the image being reviewed. The first factor (number of interactions) suggests that simpler interfaces require less time to use; the second factor, the reader, supports previous findings that radiologists vary in how fast they read screening mammography studies; the third, size of image, suggests that the speed of softcopy review is increased relative to film readings when images are significantly larger than the display size. Feedback from radiologists using the system in clinical trials and at demonstration exhibits at RSNA indicated good acceptance of the interface and easy adaptation. Radiologists indicated that they felt comfortable using the interface, and that they would use such a softcopy interface in clinical practice. Finally, preliminary work suggests that the addition of a simple interaction to incorporate computer-aided detection (CAD) results would improve reading accuracy without significantly increasing reader times.Keywords
This publication has 25 references indexed in Scilit:
- Improved mammographic interpretation of masses using computer-aided diagnosisEuropean Radiology, 2000
- IntroductionAcademic Radiology, 1999
- Contrast Limited Adaptive Histogram Equalization image processing to improve the detection of simulated spiculations in dense mammogramsJournal of Digital Imaging, 1998
- The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory settingJournal of Digital Imaging, 1997
- Does intensity windowing improve the detection of simulated calcifications in dense mammograms?Journal of Digital Imaging, 1997
- Current status of digital mammographySeminars in Ultrasound, CT and MRI, 1996
- A method for determination of optimal image enhancement for the detection of mammographic abnormalitiesJournal of Digital Imaging, 1994
- Establishing a histologic basis for false-negative mammogramsThe American Journal of Surgery, 1993
- Portal film enhancement: Technique and clinical utilityInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Breast Cancer Detection Demonstration Project: Five-Year Summary ReportCA: A Cancer Journal for Clinicians, 1982