Assessment of Visually Lossless Irreversible Image Compression: Comparison of Three Methods by Using an Image-Comparison Workstation
- 1 May 2000
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 215 (2), 543-553
- https://doi.org/10.1148/radiology.215.2.r00ap47543
Abstract
To determine the degree of irreversible image compression detectable in conservative viewing conditions. An image-comparison workstation, which alternately displayed two registered and magnified versions of an image, was used to study observer detection of image degradation introduced by irreversible compression. Five observers evaluated 20 16-bit posteroanterior digital chest radiographs compressed with Joint Photographic Experts Group (JPEG) or wavelet-based trellis-coded quantization (WTCQ) algorithms at compression ratios of 8:1-128:1 and x2 magnification by using (a) traditional two-alternative forced choice; (b) original-revealed two-alternative forced choice, in which the noncompressed image is identified to the observer; and (c) a resolution-metric method of matching test images to degraded reference images. The visually lossless threshold was between 8:1 and 16:1 for four observers. JPEG compression resulted in performance as good as that with WTCQ compression at these ratios. The original-revealed forced-choice method was faster and as sensitive as the two-alternative forced-choice method. The resolution-metric results were robust and provided information on performance above visually lossless levels. The image-comparison workstation is a versatile tool for comparative assessment of image quality. At x2 magnification, images compressed with either JPEG or WTCQ algorithms were indistinguishable from unaltered original images for most observers at compression ratios between 8:1 and 16:1, indicating that 10:1 compression is acceptable for primary image interpretation.Keywords
This publication has 23 references indexed in Scilit:
- Dynamic viewing protocols for diagnostic image comparisonPublished by SPIE-Intl Soc Optical Eng ,1999
- Detection of CT-proved pulmonary nodules: comparison of selenium-based digital and conventional screen-film chest radiographs.Radiology, 1998
- Information and image integration: project spectrumPublished by SPIE-Intl Soc Optical Eng ,1998
- Lossy compression using wavelets, block DCT, and lapped orthogonal transforms optimized with a perceptual modelPublished by SPIE-Intl Soc Optical Eng ,1997
- Chest radiography: depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography.Radiology, 1997
- The effects of lossy compression on the detection of subtle pulmonary nodulesMedical Physics, 1996
- Selenium-based digital radiography of the chest: radiologists' preference compared with film-screen radiographs.American Journal of Roentgenology, 1995
- Comparative study of wavelet and discrete cosine transform (DCT) decompositions with equivalent quantization and encoding strategies for medical imagesPublished by SPIE-Intl Soc Optical Eng ,1995
- A cost analysis of film image management and four PACS based on different network protocolsJournal of Digital Imaging, 1990
- Application of a noise-adaptive contrast sensitivity function to image data compressionOptical Engineering, 1990